{"product_id":"legrand-5kva-single-phase-isolating-transformer-hospital-ip00-042593","title":"Legrand 5kVA Single-Phase Isolating Transformer Hospital IP00 | 42593","description":"\u003cp\u003eShop Legrand 5kVA Single-Phase Isolating Transformer Hospital IP00 | 42593 In Iraq Best Prices\u003c\/p\u003e\u003cdiv lang=\"en\" dir=\"ltr\" class=\"product-container\"\u003e\n \u003cstyle\u003e\n .product-container {\n font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, sans-serif;\n max-width: 1200px;\n margin: 0 auto;\n padding: 2rem;\n color: #1a1a1a;\n line-height: 1.6;\n direction: ltr;\n }\n \n .product-title {\n font-size: 2rem;\n color: #2c3e50;\n margin-bottom: 1.5rem;\n font-weight: 600;\n border-bottom: 3px solid #3498db;\n padding-bottom: 0.5rem;\n }\n \n .product-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .features-section {\n background: #f8f9fa;\n padding: 2rem;\n border-radius: 12px;\n margin-bottom: 2rem;\n box-shadow: 0 2px 4px rgba(0,0,0,0.1);\n }\n \n .section-title {\n font-size: 1.5rem;\n color: #2c3e50;\n margin-bottom: 1rem;\n font-weight: 500;\n }\n \n .features-list {\n list-style: none;\n padding: 0;\n margin: 0;\n }\n \n .feature-item {\n position: relative;\n padding: 0.7rem 0 0.7rem 2.5rem;\n margin-bottom: 0.5rem;\n display: flex;\n align-items: center;\n }\n \n .feature-item:before {\n content: '';\n position: absolute;\n left: 0;\n top: 50%;\n transform: translateY(-50%);\n width: 0.6rem;\n height: 0.6rem;\n background-color: #3498db;\n border-radius: 50%;\n margin-right: 0.8rem;\n }\n \n .product-short-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .specs-table {\n width: 100%;\n border-collapse: collapse;\n margin-top: 1rem;\n background: white;\n box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n }\n \n .specs-table th,\n .specs-table td {\n padding: 1rem;\n border: 1px solid #e1e1e1;\n text-align: left;\n }\n \n .specs-table th {\n background-color: #f1f1f1;\n font-weight: 600;\n color: #2c3e50;\n }\n \n .specs-table tr:nth-child(even) {\n background-color: #f8f9fa;\n }\n \n .specs-table tr:hover {\n background-color: #f5f5f5;\n transition: background-color 0.3s ease;\n }\n \n @media (max-width: 768px) {\n .product-container {\n padding: 1rem;\n }\n \n .product-title {\n font-size: 1.5rem;\n }\n \n .features-section {\n padding: 1rem;\n }\n \n .specs-table th,\n .specs-table td {\n padding: 0.5rem;\n }\n }\n \u003c\/style\u003e\n \n \n \n \u003c!-- Short description --\u003e\n \u003cdiv class=\"product-short-description\"\u003e\n Premium 5kVA single-phase isolating transformer designed for hospital applications with dual temperature monitoring, electrostatic shield protection, and full compliance with IEC EN 61558-2-15 medical standards.\n \u003c\/div\u003e\n \n \u003c!-- Long description --\u003e\n \u003cdiv class=\"product-description\"\u003e\n This Legrand isolating transformer is specifically designed for hospital applications, meeting the stringent requirements of IEC EN 61558-2-15 standard. The transformer features a robust construction with primary and secondary voltages of 230V, delivering a rated apparent power of 5 kVA. It is equipped with an advanced dual temperature monitoring system utilizing both bi-metal strips and thermocouple PT100 sensors, ensuring compatibility with medical control systems and enhanced safety in critical healthcare environments.\n \n The transformer incorporates an electrostatic shield connected to a dedicated terminal, providing superior electromagnetic interference protection essential for hospital settings. Secondary\/earth leakage current is strictly limited to 0.5 mA off-load, and inrush current is constrained to 12 times the peak value of primary current, ensuring patient safety and equipment protection. The IP00 degree of protection rating indicates an open design suitable for indoor installation in controlled environments.\n \n Flexible cable terminals with 35 mm² cross-section on both primary and secondary sides facilitate easy installation and maintenance. The transformer's dimensions of 240mm width, 390mm height, and 250mm depth make it suitable for wall or cabinet mounting. Built with Type H insulation material, this isolating transformer represents a premium solution for hospital power distribution systems requiring maximum reliability and safety compliance.\n \u003c\/div\u003e\n \n \u003c!-- Features section (always included) --\u003e\n \n \u003cdiv class=\"features-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eKey Features\u003c\/h2\u003e\n \u003cul class=\"features-list\"\u003e\n \u003cli class=\"feature-item\"\u003eDual temperature monitoring system with bi-metal strips and PT100 thermocouple sensors for medical system compatibility\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eElectrostatic shield connected to dedicated terminal for superior electromagnetic interference protection\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eSecondary\/earth leakage current limited to 0.5 mA off-load ensuring patient safety\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eInrush current limited to 12 times peak primary current for equipment protection\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eType H insulation material for enhanced thermal performance and reliability\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eFlexible 35mm² cable terminals on both primary and secondary sides for easy installation\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIP00 degree of protection suitable for controlled indoor hospital environments\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eFully compliant with IEC EN 61558-2-15 standard for hospital isolating transformers\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \n \u003c!-- Specifications section (always included) --\u003e\n \n \u003cdiv class=\"specs-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n \u003ctable class=\"specs-table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\u003ctd\u003eProduct Type\u003c\/td\u003e\u003ctd\u003eSingle-Phase Isolating Transformer\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePrimary Voltage\u003c\/td\u003e\u003ctd\u003e230V AC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSecondary Voltage\u003c\/td\u003e\u003ctd\u003e230V AC with Centre Tap\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated Apparent Power\u003c\/td\u003e\u003ctd\u003e5 kVA (5000 VA)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eInsulation Type\u003c\/td\u003e\u003ctd\u003eType H Material\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDegree of Protection\u003c\/td\u003e\u003ctd\u003eIP00\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWidth\u003c\/td\u003e\u003ctd\u003e240 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eHeight\u003c\/td\u003e\u003ctd\u003e390 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDepth\u003c\/td\u003e\u003ctd\u003e250 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePrimary Cable Terminal\u003c\/td\u003e\u003ctd\u003eFlexible Cable 35 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSecondary Cable Terminal\u003c\/td\u003e\u003ctd\u003eFlexible Cable 35 mm²\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRelative Short Circuit Voltage\u003c\/td\u003e\u003ctd\u003e3.1%\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSecondary\/Earth Leakage Current\u003c\/td\u003e\u003ctd\u003e0.5 mA Off-Load (Maximum)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eInrush Current\u003c\/td\u003e\u003ctd\u003eLimited to 12 times peak primary current\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSafety Standard\u003c\/td\u003e\u003ctd\u003eIEC EN 61558-2-15\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eTemperature Monitoring\u003c\/td\u003e\u003ctd\u003eDual System: Bi-metal Strips and PT100 Thermocouple\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eElectrostatic Shield\u003c\/td\u003e\u003ctd\u003eYes, with Dedicated Terminal\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eShort-Circuit Proof\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRing Core\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePCB Mounting Suitable\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDistribution Board Mounting\u003c\/td\u003e\u003ctd\u003eNo\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eReference Number\u003c\/td\u003e\u003ctd\u003e042593\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eEAN Code\u003c\/td\u003e\u003ctd\u003e3414970971449\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eManufacturer\u003c\/td\u003e\u003ctd\u003eLegrand\u003c\/td\u003e\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\u003cp\u003eOrder Legrand 5kVA Single-Phase Isolating Transformer Hospital IP00 | 42593 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.\u003c\/p\u003e","brand":"Legrand","offers":[{"title":"Default Title","offer_id":45140996620488,"sku":"042593","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/fe9c88ec-bef8-410a-8aaa-f21f7a639a09.webp?v=1784069129","url":"https:\/\/toolmart.me\/en\/products\/legrand-5kva-single-phase-isolating-transformer-hospital-ip00-042593","provider":"TOOLMART","version":"1.0","type":"link"}