{"product_id":"jeddah-cables-medium-voltage-cable-3-6kv-to-36kv","title":"Jeddah Cables Medium Voltage Cable | 3.6KV to 36KV","description":"\u003cp data-start=\"289\" data-end=\"730\"\u003eJeddah Cables Medium Voltage Cable is designed for reliable power distribution in commercial buildings, residential developments, industrial distribution circuits, power supply stations, underground installations, cable ducts, and industrial cable trays. This cable range supports nominal system voltage ratings from \u003cstrong data-start=\"634\" data-end=\"654\"\u003e3.6KV up to 36KV\u003c\/strong\u003e, making it suitable for a wide range of medium voltage electrical networks.\u003c\/p\u003e\n\u003cp data-start=\"732\" data-end=\"1130\"\u003eThe cable is available with copper or aluminium conductors and is constructed with XLPE insulation for strong electrical performance, thermal stability, and long service life. Jeddah Cables states that its medium voltage cables are KEMA type tested and comply with IEC standards, supporting safe and dependable use in demanding indoor and outdoor applications. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1132\" data-end=\"1431\"\u003eThis product is listed as one quote-based item with four available cable construction options. Customers can add it to quote and specify the required cable option, voltage rating, conductor material, cable size, number of cores, armouring requirement, jacket type, quantity, and project application.\u003c\/p\u003e\n\u003cp data-start=\"1433\" data-end=\"1446\"\u003e\u003cstrong data-start=\"1433\" data-end=\"1446\"\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1448\" data-end=\"2157\"\u003e\n\u003cli data-section-id=\"1eoi6ty\" data-start=\"1448\" data-end=\"1513\"\u003eMedium voltage power cable for reliable electrical distribution\u003c\/li\u003e\n\u003cli data-section-id=\"1qyrrv1\" data-start=\"1514\" data-end=\"1593\"\u003eSuitable for commercial, residential, industrial, and infrastructure projects\u003c\/li\u003e\n\u003cli data-section-id=\"zldahk\" data-start=\"1594\" data-end=\"1633\"\u003eVoltage ratings from 3.6KV up to 36KV\u003c\/li\u003e\n\u003cli data-section-id=\"1nlvykd\" data-start=\"1634\" data-end=\"1683\"\u003eCopper or aluminium conductor options available\u003c\/li\u003e\n\u003cli data-section-id=\"1wd1twr\" data-start=\"1684\" data-end=\"1746\"\u003eCircular stranded compacted conductor according to IEC 60228\u003c\/li\u003e\n\u003cli data-section-id=\"t8va7g\" data-start=\"1747\" data-end=\"1810\"\u003eXLPE insulation for electrical strength and thermal stability\u003c\/li\u003e\n\u003cli data-section-id=\"16gxiws\" data-start=\"1811\" data-end=\"1853\"\u003eJacket options include PVC, LSHF, and PE\u003c\/li\u003e\n\u003cli data-section-id=\"cjvo4v\" data-start=\"1854\" data-end=\"1920\"\u003ePVC jacket option offers flame, oil, sunlight, and UV resistance\u003c\/li\u003e\n\u003cli data-section-id=\"jh13pc\" data-start=\"1921\" data-end=\"1976\"\u003eAvailable in single core and multi core constructions\u003c\/li\u003e\n\u003cli data-section-id=\"1nl7ddi\" data-start=\"1977\" data-end=\"2023\"\u003eAvailable in unarmoured and armoured options\u003c\/li\u003e\n\u003cli data-section-id=\"o2jtdn\" data-start=\"2024\" data-end=\"2102\"\u003eKEMA type tested and compliant with IEC standards according to Jeddah Cables\u003c\/li\u003e\n\u003cli data-section-id=\"9f9hv0\" data-start=\"2103\" data-end=\"2157\"\u003eSupplied on non-returnable wood drums or steel drums\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2159\" data-end=\"2187\"\u003e\u003cstrong data-start=\"2159\" data-end=\"2187\"\u003eAvailable Cable Options:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2189\" data-end=\"3277\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2189\" data-end=\"2287\"\u003e\n\u003ctr data-start=\"2189\" data-end=\"2287\"\u003e\n\u003cth data-start=\"2189\" data-end=\"2198\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eOption\u003c\/th\u003e\n\u003cth data-start=\"2198\" data-end=\"2211\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eCable Type\u003c\/th\u003e\n\u003cth data-start=\"2211\" data-end=\"2228\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eConductor Type\u003c\/th\u003e\n\u003cth data-start=\"2228\" data-end=\"2239\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eStandard\u003c\/th\u003e\n\u003cth data-start=\"2239\" data-end=\"2255\" data-col-size=\"md\" class=\"last:pe-10\"\u003eRated Voltage\u003c\/th\u003e\n\u003cth data-start=\"2255\" data-end=\"2267\" data-col-size=\"md\" class=\"last:pe-10\"\u003eConductor\u003c\/th\u003e\n\u003cth data-start=\"2267\" data-end=\"2276\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eJacket\u003c\/th\u003e\n\u003cth data-start=\"2276\" data-end=\"2287\" data-col-size=\"sm\" class=\"last:pe-10\"\u003ePacking\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2322\" data-end=\"3277\"\u003e\n\u003ctr data-start=\"2322\" data-end=\"2560\"\u003e\n\u003ctd data-start=\"2322\" data-end=\"2326\" data-col-size=\"sm\"\u003e1\u003c\/td\u003e\n\u003ctd data-start=\"2326\" data-end=\"2351\" data-col-size=\"sm\"\u003eSingle Core Unarmoured\u003c\/td\u003e\n\u003ctd data-start=\"2351\" data-end=\"2373\" data-col-size=\"sm\"\u003eCopper or Aluminium\u003c\/td\u003e\n\u003ctd data-start=\"2373\" data-end=\"2387\" data-col-size=\"sm\"\u003eIEC 60502-2\u003c\/td\u003e\n\u003ctd data-start=\"2387\" data-end=\"2451\" data-col-size=\"md\"\u003e3.6\/6 7.2KV, 6\/10 12KV, 8.7\/15 17.5KV, 12\/20 24KV, 18\/30 36KV\u003c\/td\u003e\n\u003ctd data-start=\"2451\" data-end=\"2498\" data-col-size=\"md\"\u003eCircular Stranded Compacted as per IEC 60228\u003c\/td\u003e\n\u003ctd data-start=\"2498\" data-end=\"2517\" data-col-size=\"sm\"\u003ePVC, LSHF, or PE\u003c\/td\u003e\n\u003ctd data-start=\"2517\" data-end=\"2560\" data-col-size=\"sm\"\u003eNon-returnable wood drums or steel drum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2561\" data-end=\"2797\"\u003e\n\u003ctd data-start=\"2561\" data-end=\"2565\" data-col-size=\"sm\"\u003e2\u003c\/td\u003e\n\u003ctd data-start=\"2565\" data-end=\"2588\" data-col-size=\"sm\"\u003eSingle Core Armoured\u003c\/td\u003e\n\u003ctd data-start=\"2588\" data-end=\"2610\" data-col-size=\"sm\"\u003eCopper or Aluminium\u003c\/td\u003e\n\u003ctd data-start=\"2610\" data-end=\"2624\" data-col-size=\"sm\"\u003eIEC 60502-2\u003c\/td\u003e\n\u003ctd data-start=\"2624\" data-end=\"2688\" data-col-size=\"md\"\u003e3.6\/6 7.2KV, 6\/10 12KV, 8.7\/15 17.5KV, 12\/20 24KV, 18\/30 36KV\u003c\/td\u003e\n\u003ctd data-start=\"2688\" data-end=\"2735\" data-col-size=\"md\"\u003eCircular Stranded Compacted as per IEC 60228\u003c\/td\u003e\n\u003ctd data-start=\"2735\" data-end=\"2754\" data-col-size=\"sm\"\u003ePVC, LSHF, or PE\u003c\/td\u003e\n\u003ctd data-start=\"2754\" data-end=\"2797\" data-col-size=\"sm\"\u003eNon-returnable wood drums or steel drum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2798\" data-end=\"3038\"\u003e\n\u003ctd data-start=\"2798\" data-end=\"2802\" data-col-size=\"sm\"\u003e3\u003c\/td\u003e\n\u003ctd data-start=\"2802\" data-end=\"2829\" data-col-size=\"sm\"\u003eMV Multi Core Unarmoured\u003c\/td\u003e\n\u003ctd data-start=\"2829\" data-end=\"2851\" data-col-size=\"sm\"\u003eCopper or Aluminium\u003c\/td\u003e\n\u003ctd data-start=\"2851\" data-end=\"2865\" data-col-size=\"sm\"\u003eIEC 60502-2\u003c\/td\u003e\n\u003ctd data-start=\"2865\" data-end=\"2929\" data-col-size=\"md\"\u003e3.6\/6 7.2KV, 6\/10 12KV, 8.7\/15 17.5KV, 12\/20 24KV, 18\/30 36KV\u003c\/td\u003e\n\u003ctd data-start=\"2929\" data-end=\"2976\" data-col-size=\"md\"\u003eCircular Stranded Compacted as per IEC 60228\u003c\/td\u003e\n\u003ctd data-start=\"2976\" data-end=\"2995\" data-col-size=\"sm\"\u003ePVC, LSHF, or PE\u003c\/td\u003e\n\u003ctd data-start=\"2995\" data-end=\"3038\" data-col-size=\"sm\"\u003eNon-returnable wood drums or steel drum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3039\" data-end=\"3277\"\u003e\n\u003ctd data-start=\"3039\" data-end=\"3043\" data-col-size=\"sm\"\u003e4\u003c\/td\u003e\n\u003ctd data-start=\"3043\" data-end=\"3068\" data-col-size=\"sm\"\u003eMV Multi Core Armoured\u003c\/td\u003e\n\u003ctd data-start=\"3068\" data-end=\"3090\" data-col-size=\"sm\"\u003eCopper or Aluminium\u003c\/td\u003e\n\u003ctd data-start=\"3090\" data-end=\"3104\" data-col-size=\"sm\"\u003eIEC 60502-2\u003c\/td\u003e\n\u003ctd data-start=\"3104\" data-end=\"3168\" data-col-size=\"md\"\u003e3.6\/6 7.2KV, 6\/10 12KV, 8.7\/15 17.5KV, 12\/20 24KV, 18\/30 36KV\u003c\/td\u003e\n\u003ctd data-start=\"3168\" data-end=\"3215\" data-col-size=\"md\"\u003eCircular Stranded Compacted as per IEC 60228\u003c\/td\u003e\n\u003ctd data-start=\"3215\" data-end=\"3234\" data-col-size=\"sm\"\u003ePVC, LSHF, or PE\u003c\/td\u003e\n\u003ctd data-start=\"3234\" data-end=\"3277\" data-col-size=\"sm\"\u003eNon-returnable wood drums or steel drum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"3279\" data-end=\"3298\"\u003e\u003cstrong data-start=\"3279\" data-end=\"3298\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3300\" data-end=\"4732\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3300\" data-end=\"3327\"\u003e\n\u003ctr data-start=\"3300\" data-end=\"3327\"\u003e\n\u003cth data-start=\"3300\" data-end=\"3316\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"3316\" data-end=\"3327\" data-col-size=\"xl\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3338\" data-end=\"4732\"\u003e\n\u003ctr data-start=\"3338\" data-end=\"3363\"\u003e\n\u003ctd data-start=\"3338\" data-end=\"3346\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"3346\" data-end=\"3363\" data-col-size=\"xl\"\u003eJeddah Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3364\" data-end=\"3403\"\u003e\n\u003ctd data-start=\"3364\" data-end=\"3379\" data-col-size=\"sm\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd data-start=\"3379\" data-end=\"3403\" data-col-size=\"xl\"\u003eMedium Voltage Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3404\" data-end=\"3439\"\u003e\n\u003ctd data-start=\"3404\" data-end=\"3410\" data-col-size=\"sm\"\u003eSKU\u003c\/td\u003e\n\u003ctd data-start=\"3410\" data-end=\"3439\" data-col-size=\"xl\"\u003eMEDIUM-VOLTAGE-CABLE-36KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3440\" data-end=\"3483\"\u003e\n\u003ctd data-start=\"3440\" data-end=\"3453\" data-col-size=\"sm\"\u003eCable Type\u003c\/td\u003e\n\u003ctd data-start=\"3453\" data-end=\"3483\" data-col-size=\"xl\"\u003eMedium Voltage Power Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3484\" data-end=\"3524\"\u003e\n\u003ctd data-start=\"3484\" data-end=\"3501\" data-col-size=\"sm\"\u003eConductor Type\u003c\/td\u003e\n\u003ctd data-start=\"3501\" data-end=\"3524\" data-col-size=\"xl\"\u003eCopper or Aluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3525\" data-end=\"3598\"\u003e\n\u003ctd data-start=\"3525\" data-end=\"3550\" data-col-size=\"sm\"\u003eConductor Construction\u003c\/td\u003e\n\u003ctd data-start=\"3550\" data-end=\"3598\" data-col-size=\"xl\"\u003eCircular Stranded Compacted as per IEC 60228\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3599\" data-end=\"3671\"\u003e\n\u003ctd data-start=\"3599\" data-end=\"3619\" data-col-size=\"sm\"\u003eGeneral Conductor\u003c\/td\u003e\n\u003ctd data-start=\"3619\" data-end=\"3671\" data-col-size=\"xl\"\u003eSoft annealed stranded circular copper conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3672\" data-end=\"3698\"\u003e\n\u003ctd data-start=\"3672\" data-end=\"3683\" data-col-size=\"sm\"\u003eStandard\u003c\/td\u003e\n\u003ctd data-start=\"3683\" data-end=\"3698\" data-col-size=\"xl\"\u003eIEC 60502-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3699\" data-end=\"3780\"\u003e\n\u003ctd data-start=\"3699\" data-end=\"3715\" data-col-size=\"sm\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd data-start=\"3715\" data-end=\"3780\" data-col-size=\"xl\"\u003e3.6\/6 7.2KV, 6\/10 12KV, 8.7\/15 17.5KV, 12\/20 24KV, 18\/30 36KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3781\" data-end=\"3828\"\u003e\n\u003ctd data-start=\"3781\" data-end=\"3794\" data-col-size=\"sm\"\u003eInsulation\u003c\/td\u003e\n\u003ctd data-start=\"3794\" data-end=\"3828\" data-col-size=\"xl\"\u003eXLPE Cross Linked Polyethylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3829\" data-end=\"3935\"\u003e\n\u003ctd data-start=\"3829\" data-end=\"3846\" data-col-size=\"sm\"\u003eJacket Options\u003c\/td\u003e\n\u003ctd data-start=\"3846\" data-end=\"3935\" data-col-size=\"xl\"\u003ePVC with flame, oil, sunlight, and UV resistance, LSHF, or PE LLDPE, LDPE, MDPE, HDPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3936\" data-end=\"4058\"\u003e\n\u003ctd data-start=\"3936\" data-end=\"3962\" data-col-size=\"sm\"\u003eAvailable Constructions\u003c\/td\u003e\n\u003ctd data-start=\"3962\" data-end=\"4058\" data-col-size=\"xl\"\u003eSingle core unarmoured, single core armoured, multi core unarmoured, and multi core armoured\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4059\" data-end=\"4141\"\u003e\n\u003ctd data-start=\"4059\" data-end=\"4073\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-start=\"4073\" data-end=\"4141\" data-col-size=\"xl\"\u003eMedium voltage power distribution and electrical supply networks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4142\" data-end=\"4329\"\u003e\n\u003ctd data-start=\"4142\" data-end=\"4157\" data-col-size=\"sm\"\u003eSuitable For\u003c\/td\u003e\n\u003ctd data-start=\"4157\" data-end=\"4329\" data-col-size=\"xl\"\u003eCommercial buildings, residential buildings, industrial distribution circuits, power supply stations, underground installations, cable ducts, and industrial cable trays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4330\" data-end=\"4383\"\u003e\n\u003ctd data-start=\"4330\" data-end=\"4340\" data-col-size=\"sm\"\u003ePacking\u003c\/td\u003e\n\u003ctd data-start=\"4340\" data-end=\"4383\" data-col-size=\"xl\"\u003eNon-returnable wood drums or steel drum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4384\" data-end=\"4548\"\u003e\n\u003ctd data-start=\"4384\" data-end=\"4404\" data-col-size=\"sm\"\u003eAvailable Options\u003c\/td\u003e\n\u003ctd data-start=\"4404\" data-end=\"4548\" data-col-size=\"xl\"\u003eCable option, voltage rating, conductor material, cable size, number of cores, armouring, jacket type, drum length, and project requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4549\" data-end=\"4732\"\u003e\n\u003ctd data-start=\"4549\" data-end=\"4562\" data-col-size=\"sm\"\u003eQuote Note\u003c\/td\u003e\n\u003ctd data-start=\"4562\" data-end=\"4732\" data-col-size=\"xl\"\u003ePlease mention cable option, voltage rating, conductor material, size, number of cores, armouring type, jacket type, quantity, and application when requesting a quote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"4734\" data-end=\"4757\"\u003e\u003cstrong data-start=\"4734\" data-end=\"4757\"\u003eUsage Instructions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"4759\" data-end=\"5321\"\u003e\n\u003cli data-section-id=\"1rddc24\" data-start=\"4759\" data-end=\"4831\"\u003eSelect the required cable construction from the available four options\u003c\/li\u003e\n\u003cli data-section-id=\"16bcthv\" data-start=\"4832\" data-end=\"4933\"\u003eConfirm voltage rating, conductor material, cable size, and number of cores based on project design\u003c\/li\u003e\n\u003cli data-section-id=\"mv6x2c\" data-start=\"4934\" data-end=\"5016\"\u003eChoose armoured or unarmoured construction according to installation environment\u003c\/li\u003e\n\u003cli data-section-id=\"3z35n\" data-start=\"5017\" data-end=\"5114\"\u003eSelect the jacket material according to fire, UV, oil, sunlight, and environmental requirements\u003c\/li\u003e\n\u003cli data-section-id=\"1gtci3h\" data-start=\"5115\" data-end=\"5187\"\u003eSpecify quantity, drum length, and application when requesting a quote\u003c\/li\u003e\n\u003cli data-section-id=\"1xnecaq\" data-start=\"5188\" data-end=\"5321\"\u003eInstallation should be completed by qualified electrical professionals according to applicable standards and project specifications\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jeddah Cables","offers":[{"title":"Default Title","offer_id":45110764503240,"sku":"MEDIUM-VOLTAGE-CABLE-36KV","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/ChatGPTImageJun6_2026_07_48_13PM.png?v=1780764576","url":"https:\/\/toolmart.me\/en\/products\/jeddah-cables-medium-voltage-cable-3-6kv-to-36kv","provider":"TOOLMART","version":"1.0","type":"link"}