{"product_id":"jeddah-cables-hv-cable-132kv","title":"Jeddah Cables HV Cable | 132KV","description":"\u003cp data-start=\"258\" data-end=\"597\"\u003eJeddah Cables HV Cable is a high voltage power cable designed for reliable and efficient power transmission over long distances. It is suitable for demanding utility, infrastructure, industrial, and power distribution applications where electrical performance, mechanical strength, and durability are essential.\u003c\/p\u003e\n\u003cp data-start=\"599\" data-end=\"1047\"\u003eThe cable is manufactured with high quality insulation materials such as XLPE, which provides strong resistance to thermal stress and electrical breakdown at elevated voltage levels. It is available with copper or aluminium conductors and multiple voltage ratings including 66KV, 69KV, 110KV, 115KV, and 132KV. According to Jeddah Cables, the HV cable range is KEMA type tested and complies with IEC standards. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1049\" data-end=\"1507\"\u003eJeddah Cables HV Cable is available with metallic sheath options such as Copper Wire Screen, Lead Sheath, a combination of both, or Smooth Aluminum Sheath. The outer jacket can be supplied in PE materials including LLDPE, LDPE, MDPE, or HDPE depending on project requirements. Customers can add this product to quote and specify the required voltage rating, conductor material, conductor size, metallic sheath, jacket type, quantity, and project application.\u003c\/p\u003e\n\u003cp data-start=\"1509\" data-end=\"1522\"\u003e\u003cstrong data-start=\"1509\" data-end=\"1522\"\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1524\" data-end=\"2275\"\u003e\n\u003cli data-section-id=\"o8ndqm\" data-start=\"1524\" data-end=\"1590\"\u003eHigh voltage cable for reliable long distance power transmission\u003c\/li\u003e\n\u003cli data-section-id=\"4c1lra\" data-start=\"1591\" data-end=\"1674\"\u003eSuitable for utility, infrastructure, industrial, and power distribution projects\u003c\/li\u003e\n\u003cli data-section-id=\"xrpdl8\" data-start=\"1675\" data-end=\"1741\"\u003eAvailable in 66KV, 69KV, 110KV, 115KV, and 132KV voltage ratings\u003c\/li\u003e\n\u003cli data-section-id=\"1nlvykd\" data-start=\"1742\" data-end=\"1791\"\u003eCopper or aluminium conductor options available\u003c\/li\u003e\n\u003cli data-section-id=\"mgb0q9\" data-start=\"1792\" data-end=\"1858\"\u003eXLPE insulation for thermal stability and electrical performance\u003c\/li\u003e\n\u003cli data-section-id=\"fzz131\" data-start=\"1859\" data-end=\"1968\"\u003eMetallic sheath options include Copper Wire Screen, Lead Sheath, combined sheath, or Smooth Aluminum Sheath\u003c\/li\u003e\n\u003cli data-section-id=\"lf3ckt\" data-start=\"1969\" data-end=\"2024\"\u003ePE jacket options include LLDPE, LDPE, MDPE, and HDPE\u003c\/li\u003e\n\u003cli data-section-id=\"1693vkg\" data-start=\"2025\" data-end=\"2080\"\u003eCircular stranded compacted conductor up to 630 sq mm\u003c\/li\u003e\n\u003cli data-section-id=\"srfv8v\" data-start=\"2081\" data-end=\"2138\"\u003eSegmental conductor up to 2500 sq mm Miliken conductors\u003c\/li\u003e\n\u003cli data-section-id=\"o2jtdn\" data-start=\"2139\" data-end=\"2217\"\u003eKEMA type tested and compliant with IEC standards according to Jeddah Cables\u003c\/li\u003e\n\u003cli data-section-id=\"mmio4v\" data-start=\"2218\" data-end=\"2275\"\u003eSupplied on returnable steel drums for project delivery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2277\" data-end=\"2296\"\u003e\u003cstrong data-start=\"2277\" data-end=\"2296\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2298\" data-end=\"3499\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2298\" data-end=\"2325\"\u003e\n\u003ctr data-start=\"2298\" data-end=\"2325\"\u003e\n\u003cth data-start=\"2298\" data-end=\"2314\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2314\" data-end=\"2325\" data-col-size=\"lg\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2336\" data-end=\"3499\"\u003e\n\u003ctr data-start=\"2336\" data-end=\"2361\"\u003e\n\u003ctd data-start=\"2336\" data-end=\"2344\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"2344\" data-end=\"2361\" data-col-size=\"lg\"\u003eJeddah Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2362\" data-end=\"2389\"\u003e\n\u003ctd data-start=\"2362\" data-end=\"2377\" data-col-size=\"sm\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd data-start=\"2377\" data-end=\"2389\" data-col-size=\"lg\"\u003eHV Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2390\" data-end=\"2414\"\u003e\n\u003ctd data-start=\"2390\" data-end=\"2396\" data-col-size=\"sm\"\u003eSKU\u003c\/td\u003e\n\u003ctd data-start=\"2396\" data-end=\"2414\" data-col-size=\"lg\"\u003eHV-CABLE-132KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2415\" data-end=\"2450\"\u003e\n\u003ctd data-start=\"2415\" data-end=\"2428\" data-col-size=\"sm\"\u003eCable Type\u003c\/td\u003e\n\u003ctd data-start=\"2428\" data-end=\"2450\" data-col-size=\"lg\"\u003eHigh Voltage Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2451\" data-end=\"2491\"\u003e\n\u003ctd data-start=\"2451\" data-end=\"2468\" data-col-size=\"sm\"\u003eConductor Type\u003c\/td\u003e\n\u003ctd data-start=\"2468\" data-end=\"2491\" data-col-size=\"lg\"\u003eCopper or Aluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2492\" data-end=\"2614\"\u003e\n\u003ctd data-start=\"2492\" data-end=\"2517\" data-col-size=\"sm\"\u003eConductor Construction\u003c\/td\u003e\n\u003ctd data-start=\"2517\" data-end=\"2614\" data-col-size=\"lg\"\u003eCircular stranded compacted up to 630 sq mm and segmental up to 2500 sq mm Miliken conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2615\" data-end=\"2674\"\u003e\n\u003ctd data-start=\"2615\" data-end=\"2626\" data-col-size=\"sm\"\u003eStandard\u003c\/td\u003e\n\u003ctd data-start=\"2626\" data-end=\"2674\" data-col-size=\"lg\"\u003eIEC 60840 and as per customer specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2675\" data-end=\"2730\"\u003e\n\u003ctd data-start=\"2675\" data-end=\"2691\" data-col-size=\"sm\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd data-start=\"2691\" data-end=\"2730\" data-col-size=\"lg\"\u003e66KV, 69KV, 110KV, 115KV, and 132KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2731\" data-end=\"2778\"\u003e\n\u003ctd data-start=\"2731\" data-end=\"2744\" data-col-size=\"sm\"\u003eInsulation\u003c\/td\u003e\n\u003ctd data-start=\"2744\" data-end=\"2778\" data-col-size=\"lg\"\u003eXLPE Cross Linked Polyethylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2779\" data-end=\"2883\"\u003e\n\u003ctd data-start=\"2779\" data-end=\"2800\" data-col-size=\"sm\"\u003eMetallic Sheathing\u003c\/td\u003e\n\u003ctd data-start=\"2800\" data-end=\"2883\" data-col-size=\"lg\"\u003eCopper Wire Screen, Lead Sheath, combination of both, or Smooth Aluminum Sheath\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2884\" data-end=\"2932\"\u003e\n\u003ctd data-start=\"2884\" data-end=\"2899\" data-col-size=\"sm\"\u003eOuter Jacket\u003c\/td\u003e\n\u003ctd data-start=\"2899\" data-end=\"2932\" data-col-size=\"lg\"\u003ePE LLDPE, LDPE, MDPE, or HDPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2933\" data-end=\"2999\"\u003e\n\u003ctd data-start=\"2933\" data-end=\"2947\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-start=\"2947\" data-end=\"2999\" data-col-size=\"lg\"\u003eHigh voltage power transmission and distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3000\" data-end=\"3126\"\u003e\n\u003ctd data-start=\"3000\" data-end=\"3015\" data-col-size=\"sm\"\u003eSuitable For\u003c\/td\u003e\n\u003ctd data-start=\"3015\" data-end=\"3126\" data-col-size=\"lg\"\u003eUtilities, substations, industrial plants, infrastructure projects, and long distance transmission networks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3127\" data-end=\"3162\"\u003e\n\u003ctd data-start=\"3127\" data-end=\"3137\" data-col-size=\"sm\"\u003ePacking\u003c\/td\u003e\n\u003ctd data-start=\"3137\" data-end=\"3162\" data-col-size=\"lg\"\u003eReturnable Steel Drum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3163\" data-end=\"3327\"\u003e\n\u003ctd data-start=\"3163\" data-end=\"3183\" data-col-size=\"sm\"\u003eAvailable Options\u003c\/td\u003e\n\u003ctd data-start=\"3183\" data-end=\"3327\" data-col-size=\"lg\"\u003eVoltage rating, conductor material, conductor size, metallic sheath, outer jacket type, drum length, and project specifications upon request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3328\" data-end=\"3499\"\u003e\n\u003ctd data-start=\"3328\" data-end=\"3341\" data-col-size=\"sm\"\u003eQuote Note\u003c\/td\u003e\n\u003ctd data-start=\"3341\" data-end=\"3499\" data-col-size=\"lg\"\u003ePlease mention voltage rating, conductor material, conductor size, sheath type, jacket material, quantity, and project application when requesting a quote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"3501\" data-end=\"3524\"\u003e\u003cstrong data-start=\"3501\" data-end=\"3524\"\u003eUsage Instructions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3526\" data-end=\"4018\"\u003e\n\u003cli data-section-id=\"1rxvzrn\" data-start=\"3526\" data-end=\"3621\"\u003eSelect the required voltage rating according to the power transmission or distribution design\u003c\/li\u003e\n\u003cli data-section-id=\"rk25m7\" data-start=\"3622\" data-end=\"3711\"\u003eConfirm conductor material and conductor size based on project engineering requirements\u003c\/li\u003e\n\u003cli data-section-id=\"1wgb03q\" data-start=\"3712\" data-end=\"3797\"\u003eChoose the metallic sheath and PE jacket type according to installation environment\u003c\/li\u003e\n\u003cli data-section-id=\"1tsnvpd\" data-start=\"3798\" data-end=\"3887\"\u003eSpecify required drum length, quantity, and project application when requesting a quote\u003c\/li\u003e\n\u003cli data-section-id=\"1cgscxp\" data-start=\"3888\" data-end=\"4018\"\u003eInstallation should be carried out by qualified electrical contractors following applicable standards and project specifications\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jeddah Cables","offers":[{"title":"Default Title","offer_id":45110764044488,"sku":"HV-CABLE-132KV","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/ChatGPTImageJun6_2026_07_38_08PM.png?v=1780763975","url":"https:\/\/toolmart.me\/en\/products\/jeddah-cables-hv-cable-132kv","provider":"TOOLMART","version":"1.0","type":"link"}