{"product_id":"jeddah-cables-fire-resistant-cable-0-6-1kv","title":"Jeddah Cables Fire Resistant Cable | 0.6 1KV","description":"\u003cp data-start=\"260\" data-end=\"663\"\u003eJeddah Cables Fire Resistant Cable is designed for electrical systems where fire safety, circuit reliability, and low smoke performance are essential. This cable range is suitable for critical building services, emergency circuits, infrastructure projects, commercial facilities, industrial sites, and applications where maintaining power during fire conditions is important.\u003c\/p\u003e\n\u003cp data-start=\"665\" data-end=\"1155\"\u003eThe cable construction includes a soft annealed stranded copper conductor, a helically applied mica glass tape fire resistant barrier, XLPE insulation, and an outer LSHF low smoke halogen free jacket. This design helps reduce fire spread, support circuit integrity, and minimize smoke and harmful halogen gas emissions during fire conditions. Jeddah Cables states that its fire resistant cable range is KEMA type tested and complies with IEC standards. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1157\" data-end=\"1375\"\u003eThis product is listed as one quote-based item with five available cable options. Customers can add it to quote and specify the required option, size, number of cores, armouring type, quantity, and project application.\u003c\/p\u003e\n\u003cp data-start=\"1377\" data-end=\"1390\"\u003e\u003cstrong data-start=\"1377\" data-end=\"1390\"\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1392\" data-end=\"2046\"\u003e\n\u003cli data-section-id=\"jdepis\" data-start=\"1392\" data-end=\"1461\"\u003eFire resistant cable for critical and emergency electrical circuits\u003c\/li\u003e\n\u003cli data-section-id=\"16u9sz7\" data-start=\"1462\" data-end=\"1520\"\u003eRated voltage 0.6 1KV for low voltage power applications\u003c\/li\u003e\n\u003cli data-section-id=\"psufqa\" data-start=\"1521\" data-end=\"1571\"\u003eSoft annealed stranded circular copper conductor\u003c\/li\u003e\n\u003cli data-section-id=\"8xs4s0\" data-start=\"1572\" data-end=\"1634\"\u003eMICA glass tape fire resistant barrier with suitable overlap\u003c\/li\u003e\n\u003cli data-section-id=\"1lyw3pt\" data-start=\"1635\" data-end=\"1701\"\u003eXLPE insulation for electrical performance and thermal stability\u003c\/li\u003e\n\u003cli data-section-id=\"aswxck\" data-start=\"1702\" data-end=\"1760\"\u003eLSHF jacket helps reduce smoke and halogen gas emissions\u003c\/li\u003e\n\u003cli data-section-id=\"95eek2\" data-start=\"1761\" data-end=\"1836\"\u003eAvailable in single core, multi core round, and multi core sector options\u003c\/li\u003e\n\u003cli data-section-id=\"guvdfs\" data-start=\"1837\" data-end=\"1889\"\u003eAvailable in unarmoured and armoured constructions\u003c\/li\u003e\n\u003cli data-section-id=\"o2jtdn\" data-start=\"1890\" data-end=\"1968\"\u003eKEMA type tested and compliant with IEC standards according to Jeddah Cables\u003c\/li\u003e\n\u003cli data-section-id=\"1t5qbh6\" data-start=\"1969\" data-end=\"2046\"\u003eSuitable for buildings, infrastructure, commercial, and industrial projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2048\" data-end=\"2076\"\u003e\u003cstrong data-start=\"2048\" data-end=\"2076\"\u003eAvailable Cable Options:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2078\" data-end=\"2713\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2078\" data-end=\"2157\"\u003e\n\u003ctr data-start=\"2078\" data-end=\"2157\"\u003e\n\u003cth data-start=\"2078\" data-end=\"2087\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eOption\u003c\/th\u003e\n\u003cth data-start=\"2087\" data-end=\"2100\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eCable Type\u003c\/th\u003e\n\u003cth data-start=\"2100\" data-end=\"2115\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eConstruction\u003c\/th\u003e\n\u003cth data-start=\"2115\" data-end=\"2126\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eStandard\u003c\/th\u003e\n\u003cth data-start=\"2126\" data-end=\"2144\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eNominal Voltage\u003c\/th\u003e\n\u003cth data-start=\"2144\" data-end=\"2157\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eArmouring\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2184\" data-end=\"2713\"\u003e\n\u003ctr data-start=\"2184\" data-end=\"2277\"\u003e\n\u003ctd data-start=\"2184\" data-end=\"2188\" data-col-size=\"sm\"\u003e1\u003c\/td\u003e\n\u003ctd data-start=\"2188\" data-end=\"2219\" data-col-size=\"sm\"\u003eSingle Core Cable Unarmoured\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2219\" data-end=\"2239\"\u003eCu MICA XLPE LSHF\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2239\" data-end=\"2253\"\u003eIEC 60502-1\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2253\" data-end=\"2263\"\u003e0.6 1KV\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2263\" data-end=\"2277\"\u003eUnarmoured\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2278\" data-end=\"2376\"\u003e\n\u003ctd data-start=\"2278\" data-end=\"2282\" data-col-size=\"sm\"\u003e2\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2282\" data-end=\"2318\"\u003eMulti Core Round Cable Unarmoured\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2318\" data-end=\"2338\"\u003eCu MICA XLPE LSHF\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2338\" data-end=\"2352\"\u003eIEC 60502-1\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2352\" data-end=\"2362\"\u003e0.6 1KV\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2362\" data-end=\"2376\"\u003eUnarmoured\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2377\" data-end=\"2476\"\u003e\n\u003ctd data-start=\"2377\" data-end=\"2381\" data-col-size=\"sm\"\u003e3\u003c\/td\u003e\n\u003ctd data-start=\"2381\" data-end=\"2418\" data-col-size=\"sm\"\u003eMulti Core Sector Cable Unarmoured\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2418\" data-end=\"2438\"\u003eCu MICA XLPE LSHF\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2438\" data-end=\"2452\"\u003eIEC 60502-1\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2452\" data-end=\"2462\"\u003e0.6 1KV\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2462\" data-end=\"2476\"\u003eUnarmoured\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2477\" data-end=\"2598\"\u003e\n\u003ctd data-start=\"2477\" data-end=\"2481\" data-col-size=\"sm\"\u003e4\u003c\/td\u003e\n\u003ctd data-start=\"2481\" data-end=\"2514\" data-col-size=\"sm\"\u003eMulti Core Round Cable Armored\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2514\" data-end=\"2538\"\u003eCU MICA XLPE AWA LSHF\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2538\" data-end=\"2560\"\u003eIEC 60502-1 BS 7846\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2560\" data-end=\"2570\"\u003e0.6 1KV\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2570\" data-end=\"2598\"\u003eAluminium Wire Armouring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2599\" data-end=\"2713\"\u003e\n\u003ctd data-start=\"2599\" data-end=\"2603\" data-col-size=\"sm\"\u003e5\u003c\/td\u003e\n\u003ctd data-start=\"2603\" data-end=\"2637\" data-col-size=\"sm\"\u003eMulti Core Sector Cable Armored\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2637\" data-end=\"2657\"\u003eCu MICA XLPE LSHF\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2657\" data-end=\"2679\"\u003eIEC 60502-1 BS 7846\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2679\" data-end=\"2689\"\u003e0.6 1KV\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2689\" data-end=\"2713\"\u003eSteel Wire Armouring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"2715\" data-end=\"2734\"\u003e\u003cstrong data-start=\"2715\" data-end=\"2734\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2736\" data-end=\"3938\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2736\" data-end=\"2763\"\u003e\n\u003ctr data-start=\"2736\" data-end=\"2763\"\u003e\n\u003cth data-start=\"2736\" data-end=\"2752\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2752\" data-end=\"2763\" data-col-size=\"lg\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2774\" data-end=\"3938\"\u003e\n\u003ctr data-start=\"2774\" data-end=\"2799\"\u003e\n\u003ctd data-start=\"2774\" data-end=\"2782\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"2782\" data-end=\"2799\" data-col-size=\"lg\"\u003eJeddah Cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2800\" data-end=\"2839\"\u003e\n\u003ctd data-start=\"2800\" data-end=\"2815\" data-col-size=\"sm\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd data-start=\"2815\" data-end=\"2839\" data-col-size=\"lg\"\u003eFire Resistant Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2840\" data-end=\"2878\"\u003e\n\u003ctd data-start=\"2840\" data-end=\"2846\" data-col-size=\"sm\"\u003eSKU\u003c\/td\u003e\n\u003ctd data-start=\"2846\" data-end=\"2878\" data-col-size=\"lg\"\u003eFIRE-RESISTANT-CABLE-0.6-1KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2879\" data-end=\"2928\"\u003e\n\u003ctd data-start=\"2879\" data-end=\"2892\" data-col-size=\"sm\"\u003eCable Type\u003c\/td\u003e\n\u003ctd data-start=\"2892\" data-end=\"2928\" data-col-size=\"lg\"\u003eFire Resistant Low Voltage Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2929\" data-end=\"2956\"\u003e\n\u003ctd data-start=\"2929\" data-end=\"2946\" data-col-size=\"sm\"\u003eConductor Type\u003c\/td\u003e\n\u003ctd data-start=\"2946\" data-end=\"2956\" data-col-size=\"lg\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2957\" data-end=\"3034\"\u003e\n\u003ctd data-start=\"2957\" data-end=\"2982\" data-col-size=\"sm\"\u003eConductor Construction\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"2982\" data-end=\"3034\"\u003eSoft annealed stranded circular copper conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3035\" data-end=\"3119\"\u003e\n\u003ctd data-start=\"3035\" data-end=\"3060\" data-col-size=\"sm\"\u003eFire Resistant Barrier\u003c\/td\u003e\n\u003ctd data-start=\"3060\" data-end=\"3119\" data-col-size=\"lg\"\u003eHelically applied mica glass tape with suitable overlap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3120\" data-end=\"3167\"\u003e\n\u003ctd data-start=\"3120\" data-end=\"3133\" data-col-size=\"sm\"\u003eInsulation\u003c\/td\u003e\n\u003ctd data-start=\"3133\" data-end=\"3167\" data-col-size=\"lg\"\u003eXLPE Cross Linked Polyethylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3168\" data-end=\"3208\"\u003e\n\u003ctd data-start=\"3168\" data-end=\"3177\" data-col-size=\"sm\"\u003eJacket\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"3177\" data-end=\"3208\"\u003eLSHF Low Smoke Halogen Free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3209\" data-end=\"3236\"\u003e\n\u003ctd data-start=\"3209\" data-end=\"3225\" data-col-size=\"sm\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"3225\" data-end=\"3236\"\u003e0.6 1KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3237\" data-end=\"3314\"\u003e\n\u003ctd data-start=\"3237\" data-end=\"3249\" data-col-size=\"sm\"\u003eStandards\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"3249\" data-end=\"3314\"\u003eIEC 60502-1 and IEC 60502-1 BS 7846 depending on cable option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3315\" data-end=\"3419\"\u003e\n\u003ctd data-start=\"3315\" data-end=\"3341\" data-col-size=\"sm\"\u003eAvailable Constructions\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"3341\" data-end=\"3419\"\u003eSingle core, multi core round, multi core sector, unarmoured, and armoured\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3420\" data-end=\"3526\"\u003e\n\u003ctd data-start=\"3420\" data-end=\"3430\" data-col-size=\"sm\"\u003ePacking\u003c\/td\u003e\n\u003ctd data-start=\"3430\" data-end=\"3526\" data-col-size=\"lg\"\u003ePlastic spools, coils, shrink wrap, or non-returnable wood drums as per customer requirement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3527\" data-end=\"3657\"\u003e\n\u003ctd data-start=\"3527\" data-end=\"3541\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-start=\"3541\" data-end=\"3657\" data-col-size=\"lg\"\u003eFire resistant power supply, emergency circuits, building services, infrastructure, and industrial installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3658\" data-end=\"3803\"\u003e\n\u003ctd data-start=\"3658\" data-end=\"3673\" data-col-size=\"sm\"\u003eSuitable For\u003c\/td\u003e\n\u003ctd data-col-size=\"lg\" data-start=\"3673\" data-end=\"3803\"\u003eCommercial buildings, residential towers, hospitals, airports, tunnels, industrial facilities, and critical electrical systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3804\" data-end=\"3938\"\u003e\n\u003ctd data-start=\"3804\" data-end=\"3817\" data-col-size=\"sm\"\u003eQuote Note\u003c\/td\u003e\n\u003ctd data-start=\"3817\" data-end=\"3938\" data-col-size=\"lg\"\u003ePlease mention cable option, size, number of cores, armouring type, quantity, and application when requesting a quote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"3940\" data-end=\"3963\"\u003e\u003cstrong data-start=\"3940\" data-end=\"3963\"\u003eUsage Instructions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3965\" data-end=\"4441\"\u003e\n\u003cli data-section-id=\"pvvnwe\" data-start=\"3965\" data-end=\"4037\"\u003eSelect the required cable option from the available five constructions\u003c\/li\u003e\n\u003cli data-section-id=\"15tgu7s\" data-start=\"4038\" data-end=\"4130\"\u003eConfirm the cable size, number of cores, and armouring requirement based on project design\u003c\/li\u003e\n\u003cli data-section-id=\"qyeemp\" data-start=\"4131\" data-end=\"4214\"\u003eUse in critical circuits where fire resistance and circuit integrity are required\u003c\/li\u003e\n\u003cli data-section-id=\"1e9yxip\" data-start=\"4215\" data-end=\"4307\"\u003eSpecify quantity, packing preference, and installation application when requesting a quote\u003c\/li\u003e\n\u003cli data-section-id=\"1xnecaq\" data-start=\"4308\" data-end=\"4441\"\u003eInstallation should be completed by qualified electrical professionals according to applicable standards and project specifications\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Jeddah Cables","offers":[{"title":"Default Title","offer_id":45110763487432,"sku":"FIRE-RESISTANT-CABLE-0.6-1KV","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/Multi-Core-Sector-Cable-Armoured.png?v=1780763541","url":"https:\/\/toolmart.me\/en\/products\/jeddah-cables-fire-resistant-cable-0-6-1kv","provider":"TOOLMART","version":"1.0","type":"link"}