{"product_id":"efaflu-submersible-vnnj-vertical-centrifugal-pump","title":"Efaflu Submersible VNNJ | Vertical Submersible Pump","description":"\u003cp data-start=\"292\" data-end=\"579\"\u003eThe Efaflu Submersible VNNJ is a standardized vertical centrifugal pump engineered for efficient fluid handling in demanding environments. Directly coupled to an electric motor, this pump ensures compact installation and reliable operation in both industrial and commercial applications.\u003c\/p\u003e\n\u003cp data-start=\"581\" data-end=\"851\"\u003eManufactured according to EN733 (DIN24255) standards, the VNNJ pump features a closed-type radial impeller that delivers consistent hydraulic performance. Its vertical design makes it ideal for installations where space optimization and submerged operation are required.\u003c\/p\u003e\n\u003cp data-start=\"853\" data-end=\"1216\"\u003eBuilt with durable materials such as cast iron and stainless steel components, the pump is suitable for continuous operation in water circulation, cooling systems, and industrial processes. Optional configurations allow customization with corrosion-resistant materials like stainless steel or zinc-free bronze, enhancing versatility across different applications.\u003c\/p\u003e\n\u003chr data-start=\"1218\" data-end=\"1221\"\u003e\n\u003ch3 data-section-id=\"1gft5qz\" data-start=\"1223\" data-end=\"1240\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1227\" data-end=\"1240\"\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1242\" data-end=\"1611\"\u003e\n\u003cli data-section-id=\"1r4wc43\" data-start=\"1242\" data-end=\"1283\"\u003eVertical submersible centrifugal pump\u003c\/li\u003e\n\u003cli data-section-id=\"1pws0e4\" data-start=\"1284\" data-end=\"1319\"\u003eDirectly coupled electric motor\u003c\/li\u003e\n\u003cli data-section-id=\"zolhpt\" data-start=\"1320\" data-end=\"1364\"\u003eManufactured to EN733 DIN24255 standards\u003c\/li\u003e\n\u003cli data-section-id=\"hvp5rp\" data-start=\"1365\" data-end=\"1417\"\u003eClosed radial impeller for efficient performance\u003c\/li\u003e\n\u003cli data-section-id=\"izbvgp\" data-start=\"1418\" data-end=\"1462\"\u003eCompact and space-saving vertical design\u003c\/li\u003e\n\u003cli data-section-id=\"4jtacf\" data-start=\"1463\" data-end=\"1512\"\u003eDurable construction for continuous operation\u003c\/li\u003e\n\u003cli data-section-id=\"cuy78a\" data-start=\"1513\" data-end=\"1564\"\u003eCustomizable materials for corrosion resistance\u003c\/li\u003e\n\u003cli data-section-id=\"1xrtovl\" data-start=\"1565\" data-end=\"1611\"\u003eSuitable for industrial and commercial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1613\" data-end=\"1616\"\u003e\n\u003ch3 data-section-id=\"e8he8i\" data-start=\"1618\" data-end=\"1641\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1622\" data-end=\"1641\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1643\" data-end=\"3194\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1643\" data-end=\"1748\"\u003e\n\u003ctr data-start=\"1643\" data-end=\"1748\"\u003e\n\u003cth data-start=\"1643\" data-end=\"1669\" data-col-size=\"sm\" class=\"\"\u003e\u003cstrong data-start=\"1645\" data-end=\"1657\"\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"1669\" data-end=\"1748\" data-col-size=\"sm\" class=\"\"\u003e\u003cstrong data-start=\"1671\" data-end=\"1682\"\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1856\" data-end=\"3194\"\u003e\n\u003ctr data-start=\"1856\" data-end=\"1959\"\u003e\n\u003ctd data-start=\"1856\" data-end=\"1881\" data-col-size=\"sm\"\u003ePump Type\u003c\/td\u003e\n\u003ctd data-start=\"1881\" data-end=\"1959\" data-col-size=\"sm\"\u003eVertical Submersible Centrifugal Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1960\" data-end=\"2063\"\u003e\n\u003ctd data-start=\"1960\" data-end=\"1985\" data-col-size=\"sm\"\u003eStandard\u003c\/td\u003e\n\u003ctd data-start=\"1985\" data-end=\"2063\" data-col-size=\"sm\"\u003eEN733 (DIN24255)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2064\" data-end=\"2166\"\u003e\n\u003ctd data-start=\"2064\" data-end=\"2089\" data-col-size=\"sm\"\u003eInstallation\u003c\/td\u003e\n\u003ctd data-start=\"2089\" data-end=\"2166\" data-col-size=\"sm\"\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2167\" data-end=\"2269\"\u003e\n\u003ctd data-start=\"2167\" data-end=\"2192\" data-col-size=\"sm\"\u003eImpeller Type\u003c\/td\u003e\n\u003ctd data-start=\"2192\" data-end=\"2269\" data-col-size=\"sm\"\u003eClosed Radial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2270\" data-end=\"2371\"\u003e\n\u003ctd data-start=\"2270\" data-end=\"2295\" data-col-size=\"sm\"\u003ePump Body Material\u003c\/td\u003e\n\u003ctd data-start=\"2295\" data-end=\"2371\" data-col-size=\"sm\"\u003eEN-GJL-250 Cast Iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2372\" data-end=\"2473\"\u003e\n\u003ctd data-start=\"2372\" data-end=\"2397\" data-col-size=\"sm\"\u003eImpeller Material\u003c\/td\u003e\n\u003ctd data-start=\"2397\" data-end=\"2473\" data-col-size=\"sm\"\u003eEN-GJL-250 Cast Iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2474\" data-end=\"2576\"\u003e\n\u003ctd data-start=\"2474\" data-end=\"2499\" data-col-size=\"sm\"\u003eShaft Material\u003c\/td\u003e\n\u003ctd data-start=\"2499\" data-end=\"2576\" data-col-size=\"sm\"\u003eAISI 420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2577\" data-end=\"2679\"\u003e\n\u003ctd data-start=\"2577\" data-end=\"2602\" data-col-size=\"sm\"\u003eMechanical Seal\u003c\/td\u003e\n\u003ctd data-start=\"2602\" data-end=\"2679\" data-col-size=\"sm\"\u003eCarbon \/ Ceramic \/ NBR or Gasket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2680\" data-end=\"2782\"\u003e\n\u003ctd data-start=\"2680\" data-end=\"2705\" data-col-size=\"sm\"\u003eO-Rings\u003c\/td\u003e\n\u003ctd data-start=\"2705\" data-end=\"2782\" data-col-size=\"sm\"\u003eEPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2783\" data-end=\"2885\"\u003e\n\u003ctd data-start=\"2783\" data-end=\"2808\" data-col-size=\"sm\"\u003eMax Column Length\u003c\/td\u003e\n\u003ctd data-start=\"2808\" data-end=\"2885\" data-col-size=\"sm\"\u003e600 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2886\" data-end=\"2988\"\u003e\n\u003ctd data-start=\"2886\" data-end=\"2911\" data-col-size=\"sm\"\u003eMax Fluid Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2911\" data-end=\"2988\" data-col-size=\"sm\"\u003eUp to 120°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2989\" data-end=\"3091\"\u003e\n\u003ctd data-start=\"2989\" data-end=\"3014\" data-col-size=\"sm\"\u003eMax Pressure\u003c\/td\u003e\n\u003ctd data-start=\"3014\" data-end=\"3091\" data-col-size=\"sm\"\u003e10 bar (16 bar optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3092\" data-end=\"3194\"\u003e\n\u003ctd data-start=\"3092\" data-end=\"3117\" data-col-size=\"sm\"\u003eMax Ambient Temp\u003c\/td\u003e\n\u003ctd data-start=\"3117\" data-end=\"3194\" data-col-size=\"sm\"\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3196\" data-end=\"3199\"\u003e\n\u003ch3 data-section-id=\"1einuet\" data-start=\"3201\" data-end=\"3222\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3205\" data-end=\"3222\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3224\" data-end=\"3349\"\u003e\n\u003cli data-section-id=\"ayt8n2\" data-start=\"3224\" data-end=\"3258\"\u003eCold and hot water circulation\u003c\/li\u003e\n\u003cli data-section-id=\"wbqg1d\" data-start=\"3259\" data-end=\"3289\"\u003eWater distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1bhu7kh\" data-start=\"3290\" data-end=\"3309\"\u003eCooling systems\u003c\/li\u003e\n\u003cli data-section-id=\"1cnorsi\" data-start=\"3310\" data-end=\"3324\"\u003eIrrigation\u003c\/li\u003e\n\u003cli data-section-id=\"16hniz6\" data-start=\"3325\" data-end=\"3349\"\u003eIndustrial processes\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Efaflu","offers":[{"title":"Default Title","offer_id":45074356142280,"sku":"VNNJ","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/VNNJ.png?v=1777751998","url":"https:\/\/toolmart.me\/en\/products\/efaflu-submersible-vnnj-vertical-centrifugal-pump","provider":"TOOLMART","version":"1.0","type":"link"}