{"product_id":"efaflu-standard-nnj-end-suction-centrifugal-pump","title":"Efaflu Standard NNJ | End Suction Centrifugal Pump","description":"\u003cp data-start=\"293\" data-end=\"588\"\u003eThe Efaflu Standard NNJ is a robust and highly efficient end suction centrifugal pump engineered according to EN733 (DIN24255) standards. Designed as a free-shaft pump, it offers flexibility for coupling with motors, making it suitable for a wide range of industrial and commercial applications.\u003c\/p\u003e\n\u003cp data-start=\"590\" data-end=\"875\"\u003eEquipped with a closed-type radial impeller made of cast iron, the NNJ pump ensures consistent hydraulic performance and durability under demanding conditions. It is particularly ideal for horizontal installations in HVAC systems, pressurization units, and water distribution networks.\u003c\/p\u003e\n\u003cp data-start=\"877\" data-end=\"1202\"\u003eThe pump is widely used in heating and cooling systems, cooling towers, and industrial processes, where reliable water circulation is critical. Optional configurations allow customization with stainless steel or bronze components for enhanced corrosion resistance, making it adaptable to various fluid types and environments.\u003c\/p\u003e\n\u003chr data-start=\"1204\" data-end=\"1207\"\u003e\n\u003ch3 data-section-id=\"1gft5qz\" data-start=\"1209\" data-end=\"1226\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1213\" data-end=\"1226\"\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1228\" data-end=\"1585\"\u003e\n\u003cli data-section-id=\"y32tf1\" data-start=\"1228\" data-end=\"1266\"\u003eFree-shaft centrifugal pump design\u003c\/li\u003e\n\u003cli data-section-id=\"igd0o9\" data-start=\"1267\" data-end=\"1321\"\u003eManufactured according to EN733 DIN24255 standards\u003c\/li\u003e\n\u003cli data-section-id=\"1sug1wt\" data-start=\"1322\" data-end=\"1368\"\u003eClosed radial impeller for high efficiency\u003c\/li\u003e\n\u003cli data-section-id=\"wsqops\" data-start=\"1369\" data-end=\"1409\"\u003eSuitable for horizontal installation\u003c\/li\u003e\n\u003cli data-section-id=\"117dgxv\" data-start=\"1410\" data-end=\"1444\"\u003eDurable cast iron construction\u003c\/li\u003e\n\u003cli data-section-id=\"bb3iwz\" data-start=\"1445\" data-end=\"1480\"\u003eFlexible motor coupling options\u003c\/li\u003e\n\u003cli data-section-id=\"1q55orv\" data-start=\"1481\" data-end=\"1535\"\u003eCustomizable materials (bronze or stainless steel)\u003c\/li\u003e\n\u003cli data-section-id=\"eughwk\" data-start=\"1536\" data-end=\"1585\"\u003eReliable performance in continuous operations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1587\" data-end=\"1590\"\u003e\n\u003ch3 data-section-id=\"e8he8i\" data-start=\"1592\" data-end=\"1615\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1596\" data-end=\"1615\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1617\" data-end=\"3067\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1617\" data-end=\"1722\"\u003e\n\u003ctr data-start=\"1617\" data-end=\"1722\"\u003e\n\u003cth data-start=\"1617\" data-end=\"1643\" data-col-size=\"sm\" class=\"\"\u003e\u003cstrong data-start=\"1619\" data-end=\"1631\"\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"1643\" data-end=\"1722\" data-col-size=\"md\" class=\"\"\u003e\u003cstrong data-start=\"1645\" data-end=\"1656\"\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1830\" data-end=\"3067\"\u003e\n\u003ctr data-start=\"1830\" data-end=\"1933\"\u003e\n\u003ctd data-start=\"1830\" data-end=\"1855\" data-col-size=\"sm\"\u003ePump Type\u003c\/td\u003e\n\u003ctd data-start=\"1855\" data-end=\"1933\" data-col-size=\"md\"\u003eEnd Suction Centrifugal Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1934\" data-end=\"2037\"\u003e\n\u003ctd data-start=\"1934\" data-end=\"1959\" data-col-size=\"sm\"\u003eStandard\u003c\/td\u003e\n\u003ctd data-start=\"1959\" data-end=\"2037\" data-col-size=\"md\"\u003eEN733 (DIN24255)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2038\" data-end=\"2140\"\u003e\n\u003ctd data-start=\"2038\" data-end=\"2063\" data-col-size=\"sm\"\u003eInstallation\u003c\/td\u003e\n\u003ctd data-start=\"2063\" data-end=\"2140\" data-col-size=\"md\"\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2141\" data-end=\"2243\"\u003e\n\u003ctd data-start=\"2141\" data-end=\"2166\" data-col-size=\"sm\"\u003eImpeller Type\u003c\/td\u003e\n\u003ctd data-start=\"2166\" data-end=\"2243\" data-col-size=\"md\"\u003eClosed Radial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2244\" data-end=\"2346\"\u003e\n\u003ctd data-start=\"2244\" data-end=\"2269\" data-col-size=\"sm\"\u003ePump Body Material\u003c\/td\u003e\n\u003ctd data-start=\"2269\" data-end=\"2346\" data-col-size=\"md\"\u003eEN-GJL-250 Cast Iron (AISI 316 optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2347\" data-end=\"2449\"\u003e\n\u003ctd data-start=\"2347\" data-end=\"2372\" data-col-size=\"sm\"\u003eImpeller Material\u003c\/td\u003e\n\u003ctd data-start=\"2372\" data-end=\"2449\" data-col-size=\"md\"\u003eEN-GJL-250 Cast Iron (Stainless Steel optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2450\" data-end=\"2552\"\u003e\n\u003ctd data-start=\"2450\" data-end=\"2475\" data-col-size=\"sm\"\u003eShaft Material\u003c\/td\u003e\n\u003ctd data-start=\"2475\" data-end=\"2552\" data-col-size=\"md\"\u003eAISI 420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2553\" data-end=\"2655\"\u003e\n\u003ctd data-start=\"2553\" data-end=\"2578\" data-col-size=\"sm\"\u003eMechanical Seal\u003c\/td\u003e\n\u003ctd data-start=\"2578\" data-end=\"2655\" data-col-size=\"md\"\u003eCarbon \/ Ceramic \/ NBR or Gasket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2656\" data-end=\"2758\"\u003e\n\u003ctd data-start=\"2656\" data-end=\"2681\" data-col-size=\"sm\"\u003eO-Rings\u003c\/td\u003e\n\u003ctd data-start=\"2681\" data-end=\"2758\" data-col-size=\"md\"\u003eEPDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2759\" data-end=\"2861\"\u003e\n\u003ctd data-start=\"2759\" data-end=\"2784\" data-col-size=\"sm\"\u003eMax Fluid Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2784\" data-end=\"2861\" data-col-size=\"md\"\u003eUp to 120°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2862\" data-end=\"2964\"\u003e\n\u003ctd data-start=\"2862\" data-end=\"2887\" data-col-size=\"sm\"\u003eMax Pressure\u003c\/td\u003e\n\u003ctd data-start=\"2887\" data-end=\"2964\" data-col-size=\"md\"\u003e10 bar (16 bar optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2965\" data-end=\"3067\"\u003e\n\u003ctd data-start=\"2965\" data-end=\"2990\" data-col-size=\"sm\"\u003eMax Ambient Temp\u003c\/td\u003e\n\u003ctd data-start=\"2990\" data-end=\"3067\" data-col-size=\"md\"\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3069\" data-end=\"3072\"\u003e\n\u003ch3 data-section-id=\"1einuet\" data-start=\"3074\" data-end=\"3095\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3078\" data-end=\"3095\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3097\" data-end=\"3305\"\u003e\n\u003cli data-section-id=\"ciapr6\" data-start=\"3097\" data-end=\"3128\"\u003eHeating and cooling systems\u003c\/li\u003e\n\u003cli data-section-id=\"ri16sb\" data-start=\"3129\" data-end=\"3151\"\u003eHVAC installations\u003c\/li\u003e\n\u003cli data-section-id=\"15ip25s\" data-start=\"3152\" data-end=\"3178\"\u003ePressurization systems\u003c\/li\u003e\n\u003cli data-section-id=\"105owq7\" data-start=\"3179\" data-end=\"3197\"\u003eCooling towers\u003c\/li\u003e\n\u003cli data-section-id=\"ae4efa\" data-start=\"3198\" data-end=\"3225\"\u003eHot water recirculation\u003c\/li\u003e\n\u003cli data-section-id=\"1bnb1gq\" data-start=\"3226\" data-end=\"3257\"\u003eWater distribution networks\u003c\/li\u003e\n\u003cli data-section-id=\"1ts7iec\" data-start=\"3258\" data-end=\"3280\"\u003eIrrigation systems\u003c\/li\u003e\n\u003cli data-section-id=\"16hniz6\" data-start=\"3281\" data-end=\"3305\"\u003eIndustrial processes\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Efaflu","offers":[{"title":"Default Title","offer_id":45074352275656,"sku":"NNJ","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/grupo-NNJ.png?v=1777751834","url":"https:\/\/toolmart.me\/en\/products\/efaflu-standard-nnj-end-suction-centrifugal-pump","provider":"TOOLMART","version":"1.0","type":"link"}