{"product_id":"efaflu-cst2-smart-hot-water-circulating-pump","title":"Efaflu Hot Water Circulating Pump | CST2 Smart","description":"\u003cp data-start=\"396\" data-end=\"646\"\u003eThe Efaflu CST2 Smart Circulating Pump is an advanced solution for domestic hot water systems, offering intelligent control and high efficiency. Designed with a wet rotor motor and permanent magnets, it ensures reliable and energy-saving performance.\u003c\/p\u003e\n\u003cp data-start=\"648\" data-end=\"904\"\u003eThis smart pump features variable speed operation with multiple control modes including proportional pressure, constant pressure, constant speed, and night mode. The integrated digital display allows easy programming and real-time monitoring of parameters.\u003c\/p\u003e\n\u003cp data-start=\"906\" data-end=\"1099\"\u003eBuilt for durability and flexibility, the CST2 Smart includes integrated overload protection, multiple mounting options, and low-noise operation, making it ideal for modern residential systems.\u003c\/p\u003e\n\u003chr data-start=\"1101\" data-end=\"1104\"\u003e\n\u003ch3 data-section-id=\"1gft5qz\" data-start=\"1106\" data-end=\"1123\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1110\" data-end=\"1123\"\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1125\" data-end=\"1459\"\u003e\n\u003cli data-section-id=\"omsyms\" data-start=\"1125\" data-end=\"1168\"\u003eCirculating pump for domestic hot water\u003c\/li\u003e\n\u003cli data-section-id=\"1769c3y\" data-start=\"1169\" data-end=\"1211\"\u003eWet rotor motor with permanent magnets\u003c\/li\u003e\n\u003cli data-section-id=\"1mzrwxe\" data-start=\"1212\" data-end=\"1249\"\u003eHigh efficiency and ERP compliant\u003c\/li\u003e\n\u003cli data-section-id=\"1gu95xq\" data-start=\"1250\" data-end=\"1276\"\u003eVariable speed control\u003c\/li\u003e\n\u003cli data-section-id=\"13qvvim\" data-start=\"1277\" data-end=\"1316\"\u003eMultiple modes including night mode\u003c\/li\u003e\n\u003cli data-section-id=\"1xn0fj1\" data-start=\"1317\" data-end=\"1368\"\u003eDigital display for easy control and monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"vzihp0\" data-start=\"1369\" data-end=\"1403\"\u003eIntegrated overload protection\u003c\/li\u003e\n\u003cli data-section-id=\"119eyif\" data-start=\"1404\" data-end=\"1427\"\u003eLow noise operation\u003c\/li\u003e\n\u003cli data-section-id=\"1ffffqy\" data-start=\"1428\" data-end=\"1459\"\u003eFlexible mounting positions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1461\" data-end=\"1464\"\u003e\n\u003ch3 data-section-id=\"e8he8i\" data-start=\"1466\" data-end=\"1489\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1470\" data-end=\"1489\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1491\" data-end=\"2206\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1491\" data-end=\"1556\"\u003e\n\u003ctr data-start=\"1491\" data-end=\"1556\"\u003e\n\u003cth data-start=\"1491\" data-end=\"1520\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1520\" data-end=\"1556\" data-col-size=\"sm\" class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1622\" data-end=\"2206\"\u003e\n\u003ctr data-start=\"1622\" data-end=\"1686\"\u003e\n\u003ctd data-start=\"1622\" data-end=\"1650\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1650\" data-end=\"1686\"\u003eDomestic hot water systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1687\" data-end=\"1751\"\u003e\n\u003ctd data-start=\"1687\" data-end=\"1715\" data-col-size=\"sm\"\u003ePump Type\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1715\" data-end=\"1751\"\u003eCirculating pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1752\" data-end=\"1816\"\u003e\n\u003ctd data-start=\"1752\" data-end=\"1780\" data-col-size=\"sm\"\u003ePump Casting\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1780\" data-end=\"1816\"\u003eG-CuSn10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1817\" data-end=\"1881\"\u003e\n\u003ctd data-start=\"1817\" data-end=\"1845\" data-col-size=\"sm\"\u003eImpeller\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1845\" data-end=\"1881\"\u003ePES GF30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1882\" data-end=\"1946\"\u003e\n\u003ctd data-start=\"1882\" data-end=\"1910\" data-col-size=\"sm\"\u003eShaft\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1910\" data-end=\"1946\"\u003eAISI 420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1947\" data-end=\"2011\"\u003e\n\u003ctd data-start=\"1947\" data-end=\"1975\" data-col-size=\"sm\"\u003eRotor Jacket\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1975\" data-end=\"2011\"\u003eAISI 316\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2012\" data-end=\"2076\"\u003e\n\u003ctd data-start=\"2012\" data-end=\"2040\" data-col-size=\"sm\"\u003eMax Liquid Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2040\" data-end=\"2076\"\u003e65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2077\" data-end=\"2141\"\u003e\n\u003ctd data-start=\"2077\" data-end=\"2105\" data-col-size=\"sm\"\u003eMax Operating Pressure\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2105\" data-end=\"2141\"\u003e10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2142\" data-end=\"2206\"\u003e\n\u003ctd data-start=\"2142\" data-end=\"2170\" data-col-size=\"sm\"\u003eMax Ambient Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2170\" data-end=\"2206\"\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2208\" data-end=\"2211\"\u003e\n\u003ch3 data-section-id=\"1einuet\" data-start=\"2213\" data-end=\"2234\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2217\" data-end=\"2234\"\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2236\" data-end=\"2327\"\u003e\n\u003cli data-section-id=\"blbv86\" data-start=\"2236\" data-end=\"2266\"\u003eDomestic hot water systems\u003c\/li\u003e\n\u003cli data-section-id=\"2horv4\" data-start=\"2267\" data-end=\"2300\"\u003eResidential water circulation\u003c\/li\u003e\n\u003cli data-section-id=\"tf74m8\" data-start=\"2301\" data-end=\"2327\"\u003eSanitary water systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Efaflu","offers":[{"title":"Default Title","offer_id":45080001872072,"sku":"CST2SMART","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/CST-SMART.png?v=1778362792","url":"https:\/\/toolmart.me\/en\/products\/efaflu-cst2-smart-hot-water-circulating-pump","provider":"TOOLMART","version":"1.0","type":"link"}