{"product_id":"eec-gsm-5-gamma-x-ray-survey-meter-dosimeter-vnim0046","title":"EEC Compact Survey Meter and Dosimeter | GSM-5","description":"\u003cp dir=\"auto\" data-start=\"278\" data-end=\"613\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe EEC GSM 5 is a compact 2 in 1 survey meter and dosimeter designed for measuring gamma radiation and X rays. Its pocket size and lightweight construction make it suitable for radiation protection, industrial inspection, radiography, nuclear power applications and civil or defence environments. \u003cspan class=\"contents\" data-content-reference-start=\"576\" data-content-reference-end=\"597\"\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"615\" data-end=\"947\"\u003eThe instrument uses an internally mounted energy compensated Geiger Müller tube and detects radiation across an energy range from 48 keV to 3 MeV. The GSM 5 measures dose rate from 0.05 mR\/h to 5000 mR\/h and accumulated dose from 0.01 mR to 9999 mR, with dose rate linearity of ±15% using Co60. \u003cspan class=\"contents\" data-content-reference-start=\"894\" data-content-reference-end=\"915\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"949\" data-end=\"1267\"\u003eA 4 digit segment LCD provides clear measurement readings, while configurable audible, visual and vibration alarms can be set throughout the operating range. The built in vibration alarm is especially useful in noisy environments where an audible warning may be difficult to hear. \u003cspan class=\"contents\" data-content-reference-start=\"1198\" data-content-reference-end=\"1219\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1269\" data-end=\"1568\"\u003eThe GSM 5 also provides diagnostic indications for overload, over range, detector failure and high voltage failure. Accumulated dose is stored in the instrument, allowing the device to operate as both a portable survey meter and a personal dose monitoring tool. \u003cspan class=\"contents\" data-content-reference-start=\"1483\" data-content-reference-end=\"1504\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1570\" data-end=\"1885\"\u003eDesigned for extended field use, the meter offers up to 1500 hours of operation from three AAA batteries. Its ABS plastic housing weighs only 110 g including batteries and measures 69 x 19.5 x 115 mm, making it easy to carry during inspections and routine radiation monitoring. \u003cspan class=\"contents\" data-content-reference-start=\"1784\" data-content-reference-end=\"1805\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"19zqy0x\" dir=\"auto\" data-start=\"1887\" data-end=\"1899\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-start=\"1901\" data-end=\"2466\"\u003e\n\u003cli data-section-id=\"12thyg8\" data-start=\"1901\" data-end=\"1936\"\u003e2 in 1 survey meter and dosimeter\u003c\/li\u003e\n\u003cli data-section-id=\"6exuhe\" data-start=\"1937\" data-end=\"1973\"\u003eDetects gamma radiation and X rays\u003c\/li\u003e\n\u003cli data-section-id=\"11lazzk\" data-start=\"1974\" data-end=\"2017\"\u003eEnergy compensated Geiger Müller detector\u003c\/li\u003e\n\u003cli data-section-id=\"jd3ii6\" data-start=\"2018\" data-end=\"2063\"\u003eEnergy detection range from 48 keV to 3 MeV\u003c\/li\u003e\n\u003cli data-section-id=\"1qpyc4e\" data-start=\"2064\" data-end=\"2105\"\u003eMeasures dose rate and accumulated dose\u003c\/li\u003e\n\u003cli data-section-id=\"labb6i\" data-start=\"2106\" data-end=\"2127\"\u003e4 digit LCD display\u003c\/li\u003e\n\u003cli data-section-id=\"1tx7miw\" data-start=\"2128\" data-end=\"2160\"\u003eUser configurable alarm levels\u003c\/li\u003e\n\u003cli data-section-id=\"u3hddj\" data-start=\"2161\" data-end=\"2198\"\u003eAudible visual and vibration alarms\u003c\/li\u003e\n\u003cli data-section-id=\"19m39ae\" data-start=\"2199\" data-end=\"2248\"\u003eSilent vibration warning for noisy environments\u003c\/li\u003e\n\u003cli data-section-id=\"1ujhcil\" data-start=\"2249\" data-end=\"2286\"\u003eOverload and over range indications\u003c\/li\u003e\n\u003cli data-section-id=\"17lnr6u\" data-start=\"2287\" data-end=\"2316\"\u003eDetector failure indication\u003c\/li\u003e\n\u003cli data-section-id=\"1961bkg\" data-start=\"2317\" data-end=\"2350\"\u003eHigh voltage failure indication\u003c\/li\u003e\n\u003cli data-section-id=\"7acd2w\" data-start=\"2351\" data-end=\"2377\"\u003eAccumulated dose storage\u003c\/li\u003e\n\u003cli data-section-id=\"1vvz4jt\" data-start=\"2378\" data-end=\"2411\"\u003eUp to 1500 hours operating time\u003c\/li\u003e\n\u003cli data-section-id=\"1s5zoam\" data-start=\"2412\" data-end=\"2440\"\u003eCompact pocket size design\u003c\/li\u003e\n\u003cli data-section-id=\"1x8cvl3\" data-start=\"2441\" data-end=\"2466\"\u003eLightweight ABS housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1yl5694\" dir=\"auto\" data-start=\"2468\" data-end=\"2486\"\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2488\" data-end=\"3156\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2488\" data-end=\"2515\"\u003e\n\u003ctr data-start=\"2488\" data-end=\"2515\"\u003e\n\u003cth data-start=\"2488\" data-end=\"2504\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2504\" data-end=\"2515\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2526\" data-end=\"3156\"\u003e\n\u003ctr data-start=\"2526\" data-end=\"2541\"\u003e\n\u003ctd data-start=\"2526\" data-end=\"2534\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"2534\" data-end=\"2541\" data-col-size=\"sm\"\u003eEEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2542\" data-end=\"2559\"\u003e\n\u003ctd data-start=\"2542\" data-end=\"2550\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2550\" data-end=\"2559\" data-col-size=\"sm\"\u003eGSM 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2560\" data-end=\"2585\"\u003e\n\u003ctd data-start=\"2560\" data-end=\"2573\" data-col-size=\"sm\"\u003eOrder Code\u003c\/td\u003e\n\u003ctd data-start=\"2573\" data-end=\"2585\" data-col-size=\"sm\"\u003eVNIM0046\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2586\" data-end=\"2627\"\u003e\n\u003ctd data-start=\"2586\" data-end=\"2597\" data-col-size=\"sm\"\u003eDetector\u003c\/td\u003e\n\u003ctd data-start=\"2597\" data-end=\"2627\" data-col-size=\"sm\"\u003eEnergy Compensated GM Tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2628\" data-end=\"2669\"\u003e\n\u003ctd data-start=\"2628\" data-end=\"2650\" data-col-size=\"sm\"\u003eRadiation Detection\u003c\/td\u003e\n\u003ctd data-start=\"2650\" data-end=\"2669\" data-col-size=\"sm\"\u003eGamma and X Ray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2670\" data-end=\"2704\"\u003e\n\u003ctd data-start=\"2670\" data-end=\"2685\" data-col-size=\"sm\"\u003eEnergy Range\u003c\/td\u003e\n\u003ctd data-start=\"2685\" data-end=\"2704\" data-col-size=\"sm\"\u003e48 keV to 3 MeV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2705\" data-end=\"2749\"\u003e\n\u003ctd data-start=\"2705\" data-end=\"2723\" data-col-size=\"sm\"\u003eDose Rate Range\u003c\/td\u003e\n\u003ctd data-start=\"2723\" data-end=\"2749\" data-col-size=\"sm\"\u003e0.05 mR\/h to 5000 mR\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2750\" data-end=\"2785\"\u003e\n\u003ctd data-start=\"2750\" data-end=\"2763\" data-col-size=\"sm\"\u003eDose Range\u003c\/td\u003e\n\u003ctd data-start=\"2763\" data-end=\"2785\" data-col-size=\"sm\"\u003e0.01 mR to 9999 mR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2786\" data-end=\"2816\"\u003e\n\u003ctd data-start=\"2786\" data-end=\"2798\" data-col-size=\"sm\"\u003eLinearity\u003c\/td\u003e\n\u003ctd data-start=\"2798\" data-end=\"2816\" data-col-size=\"sm\"\u003e±15% with Co60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2817\" data-end=\"2850\"\u003e\n\u003ctd data-start=\"2817\" data-end=\"2827\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2827\" data-end=\"2850\" data-col-size=\"sm\"\u003e4 Digit Segment LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2851\" data-end=\"2874\"\u003e\n\u003ctd data-start=\"2851\" data-end=\"2866\" data-col-size=\"sm\"\u003eDisplay Unit\u003c\/td\u003e\n\u003ctd data-start=\"2866\" data-end=\"2874\" data-col-size=\"sm\"\u003emR\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2875\" data-end=\"2914\"\u003e\n\u003ctd data-start=\"2875\" data-end=\"2884\" data-col-size=\"sm\"\u003eAlarms\u003c\/td\u003e\n\u003ctd data-start=\"2884\" data-end=\"2914\" data-col-size=\"sm\"\u003eAudio Visual and Vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2915\" data-end=\"2950\"\u003e\n\u003ctd data-start=\"2915\" data-end=\"2930\" data-col-size=\"sm\"\u003eData Storage\u003c\/td\u003e\n\u003ctd data-start=\"2930\" data-end=\"2950\" data-col-size=\"sm\"\u003eAccumulated Dose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2951\" data-end=\"2986\"\u003e\n\u003ctd data-start=\"2951\" data-end=\"2966\" data-col-size=\"sm\"\u003eBattery Life\u003c\/td\u003e\n\u003ctd data-start=\"2966\" data-end=\"2986\" data-col-size=\"sm\"\u003eUp to 1500 Hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2987\" data-end=\"3008\"\u003e\n\u003ctd data-start=\"2987\" data-end=\"2997\" data-col-size=\"sm\"\u003eBattery\u003c\/td\u003e\n\u003ctd data-start=\"2997\" data-end=\"3008\" data-col-size=\"sm\"\u003e3 x AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3009\" data-end=\"3055\"\u003e\n\u003ctd data-start=\"3009\" data-end=\"3033\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-start=\"3033\" data-end=\"3055\" data-col-size=\"sm\"\u003eMinus 10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3056\" data-end=\"3086\"\u003e\n\u003ctd data-start=\"3056\" data-end=\"3071\" data-col-size=\"sm\"\u003eConstruction\u003c\/td\u003e\n\u003ctd data-start=\"3071\" data-end=\"3086\" data-col-size=\"sm\"\u003eABS Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3087\" data-end=\"3120\"\u003e\n\u003ctd data-start=\"3087\" data-end=\"3096\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"3096\" data-end=\"3120\" data-col-size=\"sm\"\u003e110 g with Batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3121\" data-end=\"3156\"\u003e\n\u003ctd data-start=\"3121\" data-end=\"3134\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"3134\" data-end=\"3156\" data-col-size=\"sm\"\u003e69 x 19.5 x 115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-section-id=\"6o77tk\" dir=\"auto\" data-start=\"3158\" data-end=\"3182\"\u003eIncluded Accessories\u003c\/h3\u003e\n\u003cul data-start=\"3184\" data-end=\"3237\"\u003e\n\u003cli data-section-id=\"v369yw\" data-start=\"3184\" data-end=\"3210\"\u003e3 AAA alkaline batteries\u003c\/li\u003e\n\u003cli data-section-id=\"1vd20gz\" data-start=\"3211\" data-end=\"3223\"\u003eUser guide\u003c\/li\u003e\n\u003cli data-section-id=\"1k8a25j\" data-start=\"3224\" data-end=\"3237\"\u003eWrist strap\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EEC","offers":[{"title":"Default Title","offer_id":45220334403784,"sku":"GSM-5","price":1012000.0,"currency_code":"IQD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/GSM5.png?v=1790153972","url":"https:\/\/toolmart.me\/en\/products\/eec-gsm-5-gamma-x-ray-survey-meter-dosimeter-vnim0046","provider":"TOOLMART","version":"1.0","type":"link"}