{"product_id":"drager-x-dock-5300-x-am-125-calibration-system","title":"Drager X-dock 5300 Automatic Bump Test Calibration System","description":"\u003cp\u003eShop Drager X-dock 5300 Automatic Bump Test Calibration System In Iraq Best Prices\u003c\/p\u003e\u003cdiv lang=\"en\" dir=\"ltr\" class=\"product-container\"\u003e\n \u003cstyle\u003e\n .product-container {\n font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, sans-serif;\n max-width: 1200px;\n margin: 0 auto;\n padding: 2rem;\n color: #1a1a1a;\n line-height: 1.6;\n direction: ltr;\n }\n \n .product-title {\n font-size: 2rem;\n color: #2c3e50;\n margin-bottom: 1.5rem;\n font-weight: 600;\n border-bottom: 3px solid #3498db;\n padding-bottom: 0.5rem;\n }\n \n .product-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .features-section {\n background: #f8f9fa;\n padding: 2rem;\n border-radius: 12px;\n margin-bottom: 2rem;\n box-shadow: 0 2px 4px rgba(0,0,0,0.1);\n }\n \n .section-title {\n font-size: 1.5rem;\n color: #2c3e50;\n margin-bottom: 1rem;\n font-weight: 500;\n }\n \n .features-list {\n list-style: none;\n padding: 0;\n margin: 0;\n }\n \n .feature-item {\n position: relative;\n padding: 0.7rem 0 0.7rem 2.5rem;\n margin-bottom: 0.5rem;\n display: flex;\n align-items: center;\n }\n \n .feature-item:before {\n content: '';\n position: absolute;\n left: 0;\n top: 50%;\n transform: translateY(-50%);\n width: 0.6rem;\n height: 0.6rem;\n background-color: #3498db;\n border-radius: 50%;\n margin-right: 0.8rem;\n }\n \n .product-short-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .specs-table {\n width: 100%;\n border-collapse: collapse;\n margin-top: 1rem;\n background: white;\n box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n }\n \n .specs-table th,\n .specs-table td {\n padding: 1rem;\n border: 1px solid #e1e1e1;\n text-align: left;\n }\n \n .specs-table th {\n background-color: #f1f1f1;\n font-weight: 600;\n color: #2c3e50;\n }\n \n .specs-table tr:nth-child(even) {\n background-color: #f8f9fa;\n }\n \n .specs-table tr:hover {\n background-color: #f5f5f5;\n transition: background-color 0.3s ease;\n }\n \n @media (max-width: 768px) {\n .product-container {\n padding: 1rem;\n }\n \n .product-title {\n font-size: 1.5rem;\n }\n \n .features-section {\n padding: 1rem;\n }\n \n .specs-table th,\n .specs-table td {\n padding: 0.5rem;\n }\n }\n \u003c\/style\u003e\n \n \n \n \u003c!-- Short description --\u003e\n \u003cdiv class=\"product-short-description\"\u003e\n Professional automatic bump test and calibration system for X-am gas detectors with intelligent touchscreen, 8-15 second test times, and comprehensive database logging.\n \u003c\/div\u003e\n \n \u003c!-- Long description --\u003e\n \u003cdiv class=\"product-description\"\u003e\n The Drager X-dock 5300 is a professional-grade automatic bump test and calibration master station designed for efficient maintenance of gas detection equipment. This ready-to-use system is compatible with the entire X-am family of gas detectors (1\/2\/5x00 monitors) and features an intelligent touchscreen interface that automatically recognizes sensor combinations, test gases, and gas monitor connections. The system significantly reduces maintenance costs, gas flow consumption, test times, and spare parts usage through its patented Draeger valve concept.\n \n The X-dock 5300 offers rapid testing capabilities with bump tests completed in just 8 to 15 seconds, making it ideal for high-volume maintenance operations. The integrated database stores comprehensive results of all operations, testing procedures, and evaluations for complete traceability and compliance documentation. All tubing and electrical connections are internally housed for a clean, organized setup, while the replaceable seal cartridge ensures long-term reliability and easy maintenance.\n \n This intelligent calibration system comes equipped with an X-Dock Master Station and X-am 125 Module, featuring 3 test gas inlets for different test gases, plus dedicated fresh air inlet and waste gas outlet. The system operates on 24V power supply or car adapter, making it suitable for both stationary and mobile operations. Automatic alarm element tests and leak tests eliminate manual intervention, ensuring consistent, repeatable results every time. Note: Drager's own regulator (8324250) and Viton tubing are required for full operation.\n \u003c\/div\u003e\n \n \u003c!-- Features section (always included) --\u003e\n \n \u003cdiv class=\"features-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eKey Features\u003c\/h2\u003e\n \u003cul class=\"features-list\"\u003e\n \u003cli class=\"feature-item\"\u003eIntegrated touchscreen interface for easy operation and navigation\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eAutomatic sensor combination and test gas recognition\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eRapid bump testing in 8-15 seconds per device\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eComprehensive database stores all test results and evaluations\u003c\/li\u003e\u003cli class=\"feature-item\"\u003ePatented Draeger valve concept reduces gas consumption and maintenance costs\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eAutomatic alarm element and leak testing\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eInternal tubing and electrical connections for clean installation\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eReplaceable seal cartridge for extended lifespan\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eCompatible with X-am family of gas detectors (1\/2\/5x00 monitors)\u003c\/li\u003e\u003cli class=\"feature-item\"\u003e24V power supply with car adapter option\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \n \u003c!-- Specifications section (always included) --\u003e\n \n \u003cdiv class=\"specs-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n \u003ctable class=\"specs-table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\u003ctd\u003eProduct Code\u003c\/td\u003e\u003ctd\u003e8321880\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMaster Station Dimensions\u003c\/td\u003e\u003ctd\u003e120 x 130 x 250 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eModule Dimensions\u003c\/td\u003e\u003ctd\u003e90 x 145 x 250 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMaster Station Weight\u003c\/td\u003e\u003ctd\u003e1500g\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eModule Weight\u003c\/td\u003e\u003ctd\u003e920g\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePower Supply\u003c\/td\u003e\u003ctd\u003e24V power supply or car adapter\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\u003ctd\u003e0°C to 40°C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eIP Rating\u003c\/td\u003e\u003ctd\u003eIP20\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eGas Connections\u003c\/td\u003e\u003ctd\u003e3 test gas inlets, 1 fresh air inlet, 1 waste gas outlet\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eUSB Connections\u003c\/td\u003e\u003ctd\u003e3 USB 2.0 devices\/1 USB host\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eNetwork Connectivity\u003c\/td\u003e\u003ctd\u003eNetwork connection available\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBump Test Duration\u003c\/td\u003e\u003ctd\u003e8-15 seconds per device\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCertifications\u003c\/td\u003e\u003ctd\u003eCE marking\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eIncluded Components\u003c\/td\u003e\u003ctd\u003eX-Dock Master Station, X-am 125 Module, Power Supply, 3 test gas connections\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCompatibility\u003c\/td\u003e\u003ctd\u003eX-am family of gas detectors (1\/2\/5x00 monitors)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRequired Accessories\u003c\/td\u003e\u003ctd\u003eDrager Pressure Regulator (8324250) and Viton tubing\u003c\/td\u003e\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\u003cp\u003eOrder Drager X-dock 5300 Automatic Bump Test Calibration System at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":45064867315912,"sku":"8321880","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/17ba03a9-8513-4f0a-bb2e-b3b5c19c88d0.webp?v=1777150785","url":"https:\/\/toolmart.me\/en\/products\/drager-x-dock-5300-x-am-125-calibration-system","provider":"TOOLMART","version":"1.0","type":"link"}