{"product_id":"drager-x-dock-5300-pac-series-calibration-station","title":"Drager X-dock 5300 PAC Series Bump Test Calibration Station","description":"\u003cp\u003eShop Drager X-dock 5300 PAC Series Bump Test Calibration Station In Iraq Best Prices\u003c\/p\u003e\u003cdiv lang=\"en\" dir=\"ltr\" class=\"product-container\"\u003e\n \u003cstyle\u003e\n .product-container {\n font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, sans-serif;\n max-width: 1200px;\n margin: 0 auto;\n padding: 2rem;\n color: #1a1a1a;\n line-height: 1.6;\n direction: ltr;\n }\n \n .product-title {\n font-size: 2rem;\n color: #2c3e50;\n margin-bottom: 1.5rem;\n font-weight: 600;\n border-bottom: 3px solid #3498db;\n padding-bottom: 0.5rem;\n }\n \n .product-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .features-section {\n background: #f8f9fa;\n padding: 2rem;\n border-radius: 12px;\n margin-bottom: 2rem;\n box-shadow: 0 2px 4px rgba(0,0,0,0.1);\n }\n \n .section-title {\n font-size: 1.5rem;\n color: #2c3e50;\n margin-bottom: 1rem;\n font-weight: 500;\n }\n \n .features-list {\n list-style: none;\n padding: 0;\n margin: 0;\n }\n \n .feature-item {\n position: relative;\n padding: 0.7rem 0 0.7rem 2.5rem;\n margin-bottom: 0.5rem;\n display: flex;\n align-items: center;\n }\n \n .feature-item:before {\n content: '';\n position: absolute;\n left: 0;\n top: 50%;\n transform: translateY(-50%);\n width: 0.6rem;\n height: 0.6rem;\n background-color: #3498db;\n border-radius: 50%;\n margin-right: 0.8rem;\n }\n \n .product-short-description {\n font-size: 1.2rem;\n color: #2c3e50;\n margin: 1.5rem 0;\n padding: 1rem;\n background-color: #f8f9fa;\n border-left: 4px solid #3498db;\n border-radius: 4px;\n font-weight: 500;\n }\n \n .specs-table {\n width: 100%;\n border-collapse: collapse;\n margin-top: 1rem;\n background: white;\n box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n }\n \n .specs-table th,\n .specs-table td {\n padding: 1rem;\n border: 1px solid #e1e1e1;\n text-align: left;\n }\n \n .specs-table th {\n background-color: #f1f1f1;\n font-weight: 600;\n color: #2c3e50;\n }\n \n .specs-table tr:nth-child(even) {\n background-color: #f8f9fa;\n }\n \n .specs-table tr:hover {\n background-color: #f5f5f5;\n transition: background-color 0.3s ease;\n }\n \n @media (max-width: 768px) {\n .product-container {\n padding: 1rem;\n }\n \n .product-title {\n font-size: 1.5rem;\n }\n \n .features-section {\n padding: 1rem;\n }\n \n .specs-table th,\n .specs-table td {\n padding: 0.5rem;\n }\n }\n \u003c\/style\u003e\n \n \n \n \u003c!-- Short description --\u003e\n \u003cdiv class=\"product-short-description\"\u003e\n Professional bump test and calibration station for Pac 3500\/5500\/7000 detectors with automatic gas recognition, touchscreen control, and rapid 8-15 second test times\n \u003c\/div\u003e\n \n \u003c!-- Long description --\u003e\n \u003cdiv class=\"product-description\"\u003e\n The Drager X-dock 5300 is a ready-to-use bump test and calibration station designed specifically for Pac 3500, 5500, and 7000 gas detectors. This professional-grade system includes the X-Dock Master station with single Pac module capability, featuring automatic recognition of sensor combinations, test gases, and gas detection monitors. The system significantly reduces operational costs through optimized gas flow management, shortened testing times, and reduced maintenance requirements.\n \n Key operational benefits include touchscreen interface control, integrated database recording of all test results and evaluations, and customizable reporting with USB printer compatibility. The patented valve concept minimizes wear and tear on replacement parts, while the automatic leak tests and alarm element testing ensure comprehensive detector validation. Bump tests are completed in just 8 to 15 seconds, eliminating the need for manual data entry as gas cylinders are pre-stored in the system.\n \n This calibration station comes equipped with integrated tubing and electrical connections, IP20 rating, and CE marking approval. The system operates on 24V power supply or car adapter and functions reliably in ambient conditions ranging from 0°C to 40°C. For full operation, the X-Dock Gas Regulator and Viton tubing accessories are required. The compact design features replaceable seal cartridge technology for easy maintenance and extended operational life.\n \u003c\/div\u003e\n \n \u003c!-- Features section (always included) --\u003e\n \n \u003cdiv class=\"features-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eKey Features\u003c\/h2\u003e\n \u003cul class=\"features-list\"\u003e\n \u003cli class=\"feature-item\"\u003eTouchscreen interface for intuitive operation and control\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eAutomatic recognition of sensor combinations and test gases\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eRapid bump test completion in 8-15 seconds\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIntegrated database recording and customizable USB printer reporting\u003c\/li\u003e\u003cli class=\"feature-item\"\u003ePatented valve concept reduces maintenance and wear on parts\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eAutomatic leak tests and alarm element verification\u003c\/li\u003e\u003cli class=\"feature-item\"\u003ePre-stored gas cylinder data eliminates manual entry\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eReplaceable seal cartridge for easy maintenance\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIntegrated tubing and electrical connections\u003c\/li\u003e\u003cli class=\"feature-item\"\u003eIP20 rating with CE marking approval\u003c\/li\u003e\n \u003c\/ul\u003e\n \u003c\/div\u003e\n \n \u003c!-- Specifications section (always included) --\u003e\n \n \u003cdiv class=\"specs-section\"\u003e\n \u003ch2 class=\"section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n \u003ctable class=\"specs-table\"\u003e\n \u003cthead\u003e\n \u003ctr\u003e\n \u003cth\u003eSpecification\u003c\/th\u003e\n \u003cth\u003eValue\u003c\/th\u003e\n \u003c\/tr\u003e\n \u003c\/thead\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\u003ctd\u003eProduct Type\u003c\/td\u003e\u003ctd\u003eBump Test and Calibration Station\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCompatible Detectors\u003c\/td\u003e\u003ctd\u003ePac 3500, Pac 5500, Pac 7000\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eGas Connections\u003c\/td\u003e\u003ctd\u003e3 test gas inlets, 1 fresh air inlet, 1 waste gas outlet\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMaster Station Dimensions\u003c\/td\u003e\u003ctd\u003e120 x 130 x 250 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eModule Dimensions\u003c\/td\u003e\u003ctd\u003e90 x 145 x 250 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMaster Station Weight\u003c\/td\u003e\u003ctd\u003e1500g\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eModule Weight\u003c\/td\u003e\u003ctd\u003e900g\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePower Supply\u003c\/td\u003e\u003ctd\u003e24V power supply or car adapter\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\u003ctd\u003e0°C to 40°C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eIP Rating\u003c\/td\u003e\u003ctd\u003eIP20\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eApprovals\u003c\/td\u003e\u003ctd\u003eCE marking\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnectivity\u003c\/td\u003e\u003ctd\u003e3 USB 2.0 devices\/1 USB host, Network connection\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBump Test Duration\u003c\/td\u003e\u003ctd\u003e8-15 seconds\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eIncluded Components\u003c\/td\u003e\u003ctd\u003eX-Dock Master Station, Pac Module, Power Supply, 3 test gas connections\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRequired Accessories\u003c\/td\u003e\u003ctd\u003eX-Dock Gas Regulator, Viton tubing\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMaintenance Feature\u003c\/td\u003e\u003ctd\u003eReplaceable seal cartridge\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSKU\u003c\/td\u003e\u003ctd\u003e8321881\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eManufacturer\u003c\/td\u003e\u003ctd\u003eDrager Safety\u003c\/td\u003e\u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\u003cp\u003eOrder Drager X-dock 5300 PAC Series Bump Test Calibration Station at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":45064867250376,"sku":"8321881","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/a218b131-1549-458e-b9e0-f0d484770490.webp?v=1777150780","url":"https:\/\/toolmart.me\/en\/products\/drager-x-dock-5300-pac-series-calibration-station","provider":"TOOLMART","version":"1.0","type":"link"}