{"product_id":"anton-paar-alcolyzer-5001-laboratory-alcohol-meter","title":"Anton Paar Alcolyzer 5001 Laboratory Alcohol Meter","description":"\u003cp data-start=\"406\" data-end=\"488\"\u003e\u003cstrong data-start=\"434\" data-end=\"488\"\u003eShop Anton Paar Alcolyzer 5001 In Iraq Best Prices\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"490\" data-end=\"839\"\u003eThe Anton Paar Alcolyzer 5001 is a precision laboratory alcohol meter engineered for efficient and accurate beverage analysis. Designed to streamline quality control in breweries, wineries, distilleries, and beverage labs, this device provides fast alcohol determination across a wide range of products—beer, wine, sake, kombucha, spirits, and more.\u003c\/p\u003e\n\u003cp data-start=\"841\" data-end=\"1119\"\u003eFeaturing patented NIR (Near Infrared) technology, the Alcolyzer 5001 eliminates the need for distillation, delivering results within 1 to 3.5 minutes. It supports multiple beverage types with a measuring range of 0% to 65% alcohol by volume and repeatability down to 0.03% v\/v.\u003c\/p\u003e\n\u003cp data-start=\"1121\" data-end=\"1441\"\u003eThis system enhances lab efficiency by enabling over 35 additional analytical parameters (such as original extract, real extract, calories, etc.) when density data is entered manually. Its robust design includes a 10.1″ touchscreen and versatile connectivity options to seamlessly integrate into any laboratory workflow.\u003c\/p\u003e\n\u003cp data-start=\"1443\" data-end=\"1607\"\u003eIdeal for regulated environments, the Alcolyzer 5001 meets international standards for alcohol measurement and supports integration with digital lab systems (LIMS).\u003c\/p\u003e\n\u003cp data-start=\"1609\" data-end=\"1639\"\u003e\u003cstrong data-start=\"1609\" data-end=\"1639\"\u003eSpecifications \u0026amp; Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1640\" data-end=\"2057\"\u003e\n\u003cli data-start=\"1640\" data-end=\"1685\"\u003e\n\u003cp data-start=\"1642\" data-end=\"1685\"\u003eRapid alcohol analysis with no distillation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1686\" data-end=\"1748\"\u003e\n\u003cp data-start=\"1688\" data-end=\"1748\"\u003eSuitable for beer, wine, kombucha, sake, and other beverages\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1749\" data-end=\"1795\"\u003e\n\u003cp data-start=\"1751\" data-end=\"1795\"\u003ePatented NIR measurement for direct analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1796\" data-end=\"1848\"\u003e\n\u003cp data-start=\"1798\" data-end=\"1848\"\u003eCompatible with manual or automated sample filling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1849\" data-end=\"1907\"\u003e\n\u003cp data-start=\"1851\" data-end=\"1907\"\u003eSupports entry of density data for additional parameters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1908\" data-end=\"1947\"\u003e\n\u003cp data-start=\"1910\" data-end=\"1947\"\u003eIntuitive 10.1″ touchscreen operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1948\" data-end=\"1996\"\u003e\n\u003cp data-start=\"1950\" data-end=\"1996\"\u003eSeamless data export via USB, Ethernet, RS-232\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1997\" data-end=\"2057\"\u003e\n\u003cp data-start=\"1999\" data-end=\"2057\"\u003eComplies with major global standards for alcohol testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2059\" data-end=\"2088\"\u003e\u003cstrong data-start=\"2059\" data-end=\"2088\"\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2090\" data-end=\"3087\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2090\" data-end=\"2172\"\u003e\n\u003ctr data-start=\"2090\" data-end=\"2172\"\u003e\n\u003cth data-start=\"2090\" data-end=\"2130\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2130\" data-end=\"2172\" data-col-size=\"md\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2255\" data-end=\"3087\"\u003e\n\u003ctr data-start=\"2255\" data-end=\"2336\"\u003e\n\u003ctd data-start=\"2255\" data-end=\"2294\" data-col-size=\"sm\"\u003eAlcohol Measuring Range\u003c\/td\u003e\n\u003ctd data-start=\"2294\" data-end=\"2336\" data-col-size=\"md\"\u003e0% to 65% v\/v\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2337\" data-end=\"2418\"\u003e\n\u003ctd data-start=\"2337\" data-end=\"2376\" data-col-size=\"sm\"\u003eTypical Deviation to Distillation\u003c\/td\u003e\n\u003ctd data-start=\"2376\" data-end=\"2418\" data-col-size=\"md\"\u003e\u0026lt; 0.1% v\/v\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2419\" data-end=\"2500\"\u003e\n\u003ctd data-start=\"2419\" data-end=\"2458\" data-col-size=\"sm\"\u003eRepeatability (Standard Deviation)\u003c\/td\u003e\n\u003ctd data-start=\"2458\" data-end=\"2500\" data-col-size=\"md\"\u003e0.03% v\/v\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2501\" data-end=\"2582\"\u003e\n\u003ctd data-start=\"2501\" data-end=\"2540\" data-col-size=\"sm\"\u003eMeasuring Time\u003c\/td\u003e\n\u003ctd data-start=\"2540\" data-end=\"2582\" data-col-size=\"md\"\u003e1 to 3.5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2583\" data-end=\"2663\"\u003e\n\u003ctd data-start=\"2583\" data-end=\"2622\" data-col-size=\"sm\"\u003eSample Volume\u003c\/td\u003e\n\u003ctd data-start=\"2622\" data-end=\"2663\" data-col-size=\"md\"\u003e20 mL (syringe) \/ 40 mL (sampler)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2664\" data-end=\"2745\"\u003e\n\u003ctd data-start=\"2664\" data-end=\"2703\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2703\" data-end=\"2745\" data-col-size=\"md\"\u003e10.1″ TFT WXGA Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2746\" data-end=\"2842\"\u003e\n\u003ctd data-start=\"2746\" data-end=\"2785\" data-col-size=\"sm\"\u003eConnectivity\u003c\/td\u003e\n\u003ctd data-start=\"2785\" data-end=\"2842\" data-col-size=\"md\"\u003e4×USB 2.0, 1×USB OTG, 1×RS-232, 1×Ethernet, 1×CAN Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2843\" data-end=\"2923\"\u003e\n\u003ctd data-start=\"2843\" data-end=\"2882\" data-col-size=\"sm\"\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd data-start=\"2882\" data-end=\"2923\" data-col-size=\"md\"\u003e526 mm × 347 mm × 230 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2924\" data-end=\"3005\"\u003e\n\u003ctd data-start=\"2924\" data-end=\"2963\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2963\" data-end=\"3005\" data-col-size=\"md\"\u003eApprox. 17.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3006\" data-end=\"3087\"\u003e\n\u003ctd data-start=\"3006\" data-end=\"3045\" data-col-size=\"sm\"\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd data-start=\"3045\" data-end=\"3087\" data-col-size=\"md\"\u003e+18°C to +32°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"3089\" data-end=\"3253\"\u003e\u003cstrong data-start=\"3089\" data-end=\"3253\"\u003eOrder Anton Paar Alcolyzer 5001 at wholesale prices for companies and factories in Iraq and Middle East, get the best deals on bulk purchases, contact us today.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Anton Paar","offers":[{"title":"Default Title","offer_id":44839499563208,"sku":"Alcolyzer-5001","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/download-2025-11-08T194052.683.webp?v=1762620064","url":"https:\/\/toolmart.me\/en\/products\/anton-paar-alcolyzer-5001-laboratory-alcohol-meter","provider":"TOOLMART","version":"1.0","type":"link"}