{"product_id":"amprobe-acd-14-pro-eur-clamp-meter","title":"Amprobe Clamp Meter – Dual Display 600A TRMS Multimeter | ACD-14-PRO-EUR","description":"\u003cp data-mce-fragment=\"1\"\u003eThe \u003cstrong data-mce-fragment=\"1\"\u003eAmprobe ACD-14-PRO-EUR Clamp Meter\u003c\/strong\u003e is designed to meet the needs of \u003cstrong data-mce-fragment=\"1\"\u003eHVAC and electrical professionals\u003c\/strong\u003e, offering a \u003cstrong data-mce-fragment=\"1\"\u003elarge dual backlit LCD\u003c\/strong\u003e that allows \u003cstrong data-mce-fragment=\"1\"\u003esimultaneous display of voltage and current measurements\u003c\/strong\u003e for easy troubleshooting. The \u003cstrong data-mce-fragment=\"1\"\u003eTrue RMS\u003c\/strong\u003e feature ensures accurate readings in noisy electrical environments, making it a \u003cstrong data-mce-fragment=\"1\"\u003ereliable tool for both residential and industrial applications\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWith its \u003cstrong data-mce-fragment=\"1\"\u003eAmp-Tip function\u003c\/strong\u003e, this clamp meter provides \u003cstrong data-mce-fragment=\"1\"\u003eprecise low-current measurements down to 0.1A\u003c\/strong\u003e, making it suitable for both \u003cstrong data-mce-fragment=\"1\"\u003esmall and large diameter wires\u003c\/strong\u003e. The \u003cstrong data-mce-fragment=\"1\"\u003einrush current measurement\u003c\/strong\u003e feature is essential for monitoring \u003cstrong data-mce-fragment=\"1\"\u003emotor startups\u003c\/strong\u003e, while the \u003cstrong data-mce-fragment=\"1\"\u003elow-pass filter (LPF)\u003c\/strong\u003e ensures \u003cstrong data-mce-fragment=\"1\"\u003eaccurate readings on variable frequency drives (VFDs)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe \u003cstrong data-mce-fragment=\"1\"\u003enon-contact voltage detection\u003c\/strong\u003e (VoltTect) enhances safety by allowing \u003cstrong data-mce-fragment=\"1\"\u003elive wire detection without direct contact\u003c\/strong\u003e, reducing the risk of electrical hazards.\u003c\/p\u003e\n\u003chr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTrue RMS measurement\u003c\/strong\u003e for accurate readings in complex electrical environments.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e600A AC current measurement\u003c\/strong\u003e for industrial and commercial applications.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e600V AC\/DC voltage measurement\u003c\/strong\u003e for a wide range of electrical tests.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eLow-pass filter (LPF)\u003c\/strong\u003e for precise voltage and current readings on \u003cstrong data-mce-fragment=\"1\"\u003eVFDs and other noisy circuits\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInrush current measurement\u003c\/strong\u003e for motor and equipment startup diagnostics.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAmp-Tip function\u003c\/strong\u003e for accurate low-current readings down to \u003cstrong data-mce-fragment=\"1\"\u003e0.1A\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eNon-contact voltage detection (VoltTect)\u003c\/strong\u003e for added safety.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDual display with backlight\u003c\/strong\u003e for \u003cstrong data-mce-fragment=\"1\"\u003esimultaneous voltage and current readings\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCapacitance measurement up to 3000 µF\u003c\/strong\u003e, ideal for HVAC applications.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eResistance measurement up to 40MΩ\u003c\/strong\u003e for troubleshooting circuits.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFrequency measurement up to 10 kHz\u003c\/strong\u003e for motor and electronic system diagnostics.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTemperature measurement (-40°C to 400°C)\u003c\/strong\u003e with Type-K thermocouple for HVAC testing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable data-mce-fragment=\"1\"\u003e\n\u003cthead data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003cth data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAC Current Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eUp to \u003cstrong data-mce-fragment=\"1\"\u003e600A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAC\/DC Voltage Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eUp to \u003cstrong data-mce-fragment=\"1\"\u003e600V\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eResistance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eUp to \u003cstrong data-mce-fragment=\"1\"\u003e40MΩ\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCapacitance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eUp to \u003cstrong data-mce-fragment=\"1\"\u003e3000 µF\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFrequency Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eUp to \u003cstrong data-mce-fragment=\"1\"\u003e10 kHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTemperature Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e-40°C to 400°C\u003c\/strong\u003e (-40°F to 752°F) with Type-K thermocouple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eLow-Pass Filter (LPF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eYes, for variable frequency drives (VFDs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInrush Current Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eYes, for motor startup analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAmp-Tip Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eYes, for precise \u003cstrong data-mce-fragment=\"1\"\u003elow-current measurement down to 0.1A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eNon-Contact Voltage Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eYes, VoltTect Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDual Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eYes, with backlight for \u003cstrong data-mce-fragment=\"1\"\u003esimultaneous voltage and current display\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eJaw Opening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e30mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSafety Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCAT III 600V\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAuto Power-Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eYes, for battery conservation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e9V Battery (included)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e229 × 80 × 49 mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e380 g\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's Included:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eAmprobe ACD-14-PRO-EUR Clamp Meter\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHigh-Quality Test Leads\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eType-K Thermocouple Probe\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCarrying Case\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePre-installed 9V Battery\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eUser Manual\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Amprobe","offers":[{"title":"Default Title","offer_id":44438736044232,"sku":"ACD-14-PRO-EUR","price":0.0,"currency_code":"IQD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/9761\/7864\/files\/download-2025-02-10T140638.682.webp?v=1739185663","url":"https:\/\/toolmart.me\/en\/products\/amprobe-acd-14-pro-eur-clamp-meter","provider":"TOOLMART","version":"1.0","type":"link"}